Functional Integrity of Natural Gas Storage in Depleted Hydrocarbon Reservoirs and Aquifer Reservoirs
Name übersetzen
NORM herausgegeben am 1.9.2023
Bezeichnung normen: API RP 1171-ed.2
Ausgabedatum normen: 1.9.2023
SKU: NS-1156466
Zahl der Seiten: 72
Gewicht ca.: 216 g (0.48 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen API
API RP 1171, 2nd Edition, November 2022 - Functional Integrity of Natural Gas Storage in Depleted Hydrocarbon Reservoirs and Aquifer Reservoirs
This Recommended Practice (RP) applies to natural gas storage in depleted oil and gas reservoirs and aquifer reservoirs, and focuses on storage well, reservoir, and fluid management for functional integrity in design, construction, operation, monitoring, maintenance, and documentation practices. The scope does not include pipelines, gas conditioning and liquid handling, compressors, and ancillary facilities associated with storage. Storage design, construction, operation, and maintenance include activities in risk management, site security, safety, emergency preparedness, and procedural documentation and training to embed human and organizational competence in the management of storage facilities. This RP embodies historical knowledge and experience and emphasizes the need for case-by-case and site-specific conditional assessments.
This RP applies to both existing and newly constructed facilities. However, Section 5 and Section 7 apply to new facilities, and facilities undergoing significant expansion. Section 6 applies to new well construction and remediation of a new or existing well. Specific portions of Section 5 and Section 6 may be applicable to existing reservoirs and wells as risk analysis, the availability of new data, or other information or conditions over the life of the facility warrants re-assessment. Figure 1 provides a chart showing the flow of functional integrity assurance activities through the design, operation, and maintenance of storage facilities, with references to the sections within this RP containing guidance for those activities. Applicable distinctions for aquifer facilities are identified within each section as necessary. The term “Replacement,” as used in this document, refers to the complete replacement of a facility unit, as, for example, when an existing well is abandoned and replaced with a new well. This document recommends that operators manage integrity through monitoring, maintenance, and remediation practices and apply specific integrity assessments on a case-by-case basis.
The contents of this RP are not all inclusive or intended to replace the utilization of detailed information and procedures found in textbooks, manuals, technical papers, or other documents.
This document is intended to supplement, but not replace, applicable local, state, and federal regulations.
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-12-23 (Zahl der Positionen: 2 217 157)
© Copyright 2024 NORMSERVIS s.r.o.