Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Practice for Joint Acceptance Testing of Installed Precast Concrete Pipe Sewer Lines
Name übersetzen
NORM herausgegeben am 1.10.2022
Bezeichnung normen: ASTM C1103-22
Ausgabedatum normen: 1.10.2022
SKU: NS-1087623
Zahl der Seiten: 3
Gewicht ca.: 9 g (0.02 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
ICS Number Code 23.040.50 (Pipes and fittings of other materials)
Significance and Use | ||||
5.1?This is not a routine test. The values recorded are applicable only to the sewer being tested and at the time of testing. |
||||
1. Scope | ||||
1.1?This practice covers procedures for testing the joints of installed precast concrete pipe sewer lines, when using either air or water under low pressure to demonstrate the integrity of the joint and the construction procedures. This practice is used for testing precast concrete sewer lines utilizing rubber gasket sealed joints. Note 1:?The user of this practice is advised that methods
described herein may also be used as a preliminary test to enable
the manufacturer or installer to demonstrate the condition of sewer
pipe prior to delivery.
1.2?The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. Note 2:?The owner shall specify the following: who will
conduct, observe, and furnish labor, material, and measuring
devices and pay for the tests; who is responsible for determining
local ground conditions; and whether an air or water test is to be
used.
Note 3:?The user of this practice is advised that test
criteria presented in this practice are similar to those in general
use. Pipe shall be accepted by infiltration or exfiltration testing
utilizing Practice C969
(C969M).
Note 4:?Test times tabulated and the rate of air loss in this
practice are based on successful testing of installed pipelines.
However, since air and water have different physical properties,
retests of some pipelines not meeting field air tests have been
successful when tested with water.
1.3?This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.4?This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |
||||
2. Referenced Documents | ||||
|
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Vorschriften verwenden?
Wir bieten Ihnen Lösungen, damit Sie immer nur die gültigen (aktuellen) legislativen Vorschriften verwenden könnten.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-09-15 (Zahl der Positionen: 2 433 670)
© Copyright 2024 NORMSERVIS s.r.o.