Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Test Method for Nondestructive Assay of Special Nuclear Material in Low Density Scrap and Waste by Segmented Passive Gamma-Ray Scanning
Automatische name übersetzung:
Standard-Testverfahren für die zerstörungsfreie Bestimmung von Sonderkernmaterial in Low Density Schrott und Abfall durch segmentierte Passive Gammastrahlen-Scanning
NORM herausgegeben am 1.1.2010
Bezeichnung normen: ASTM C1133/C1133M-10
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.1.2010
SKU: NS-9646
Zahl der Seiten: 17
Gewicht ca.: 51 g (0.11 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
nondestructive assay, scrap, segmented gamma-ray scanning, special nuclear material, waste, Nuclear scrap and waste materials, Radiation exposure--nuclear materials/applications, Radionuclides, Segmented gamma-ray scanning, Assay, Attenuation, Calibration--nuclear analysis instrumentation, Error propagation, Gamma radiation--nuclear materials/applications, Gamma-ray spectrometry, Nondestructive evaluation (NDE)--nuclear applications, SNM (special nuclear materials), Transmission
Significance and Use | ||||||||||||||||||||||||
Segmented gamma-ray scanning provides a nondestructive means of measuring the nuclide content of scrap and waste where the specific nature of the matrix and the chemical form and relationship between the nuclide and matrix may be unknown. The procedure can serve as a diagnostic tool that provides a vertical profile of transmission and nuclide concentration within the item. Item preparation is generally limited to good waste/scrap segregation practices that produce relatively homogeneous items that are required for any successful waste/inventory management and assay scheme, regardless of the measurement method used. Also, process knowledge should be used, when available, as part of a waste management program to complement information on item parameters, container properties, and the appropriateness of calibration factors. To obtain the lowest detection levels, a two-pass assay should be used. The two-pass assay also reduces problems related to potential interferences between transmission peaks and assay peaks. For items with higher activities, a single-pass assay may be used to increase throughput. |
||||||||||||||||||||||||
1. Scope | ||||||||||||||||||||||||
1.1 This test method covers the transmission-corrected nondestructive assay (NDA) of gamma-ray emitting special nuclear materials (SNMs), most commonly 235U, 239Pu, and 241Am, in low-density scrap or waste, packaged in cylindrical containers. The method can also be applied to NDA of other gamma-emitting nuclides including fission products. High-resolution gamma-ray spectroscopy is used to detect and measure the nuclides of interest and to measure and correct for gamma-ray attenuation in a series of horizontal segments (collimated gamma detector views) of the container. Corrections are also made for counting losses occasioned by signal processing limitations (1-3). 1.2 There are currently several systems in use or under development for determining the attenuation corrections for NDA of radioisotopic materials (4-8). A related technique, tomographic gamma-ray scanning (TGS), is not included in this test method (9, 10, 11). 1.2.1 This test method will cover two implementations of the Segmented Gamma Scanning (SGS) procedure: (1) Isotope Specific (Mass) Calibration, the original SGS procedure, uses standards of known radionuclide masses to determine detector response in a mass versus corrected count rate calibration that applies only to those specific radionuclides for which it is calibrated, and (2) Efficiency Curve Calibration, an alternative method, typically uses non-SNM radionuclide sources to determine system detection efficiency vs. gamma energy and thereby calibrate for all gamma-emitting radionuclides of interest (12). 1.2.1.1 Efficiency Curve Calibration, over the energy range for which the efficiency is defined, has the advantage of providing calibration for many gamma-emitting nuclides for which half-life and gamma emission intensity data are available. 1.3 The assay technique may be applicable to loadings up to several hundred grams of nuclide in a 208-L [55-gal] drum, with more restricted ranges to be applicable depending on specific packaging and counting equipment considerations. 1.4 Measured transmission values must be available for use in calculation of segment-specific attenuation corrections at the energies of analysis. 1.5 A related method, SGS with calculated correction factors based on item content and density, is not included in this standard. 1.6 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. 1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in Section 10. |
||||||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||||||
|
Historisch
1.7.2013
Historisch
1.6.2008
Historisch
1.1.2012
Historisch
1.6.2009
Historisch
1.1.2010
Historisch
1.6.2011
Bereitstellung von aktuellen Informationen über legislative Vorschriften in der Sammlung der Gesetze bis zum Jahr 1945.
Aktualisierung 2x pro Monat!
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-11-04 (Zahl der Positionen: 2 209 323)
© Copyright 2024 NORMSERVIS s.r.o.