Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Guide to Procedures for Calibrating Automatic Pedestrian SNM Monitors
Automatische name übersetzung:
Standard-Leitfaden für die Verfahren für die Kalibrierung Automatische Fußgänger SNM Monitore
NORM herausgegeben am 1.6.2011
Bezeichnung normen: ASTM C1189-11
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.6.2011
SKU: NS-9918
Zahl der Seiten: 9
Gewicht ca.: 27 g (0.06 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
gamma radiation, material control and accountability, neutron radiation, nuclear materials management, radiation detectors, radiation monitors, safeguards, security,Calibration--nuclear analysis instrumentation, Plutonium, Radiation, SNM (special nuclear materials), Uranium, ICS Number Code 17.240 (Radiation measurements)
Significance and Use | ||||||||||
SNM monitors are an effective means to search pedestrians for concealed SNM. Maintaining monitor effectiveness rests on appropriate calibration and adjustment being part of a continuing maintenance program. The significance of this guide for monitor users who must detect SNM is to describe calibration and adjustment procedures for the purpose. The significance of this guide for monitor manufacturers is to describe calibration procedures, particularly for detecting forms of SNM that may not be readily available to them. |
||||||||||
1. Scope | ||||||||||
1.1 This guide covers calibrating the energy response of the radiation detectors and setting the discriminator and alarm thresholds used in automatic pedestrian special nuclear material (SNM) monitors. 1.2 Automatic pedestrian SNM Monitors and their application are described in Guide C1112, which suggests that the monitors be calibrated and tested when installed and that, thereafter, the calibration should be checked and the monitor tested with SNM at three-month intervals. 1.3 Dependable operation of SNM monitors rests, in part, on an effective program to test, calibrate, and maintain them. The procedures and methods described in this guide may help both to achieve dependable operation and obtain timely warning of misoperation. |
||||||||||
2. Referenced Documents | ||||||||||
|
Historisch
1.11.2006
Historisch
1.6.2012
Historisch
1.11.2013
Historisch
1.7.2010
Historisch
1.11.2011
Historisch
1.7.2010
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-11-22 (Zahl der Positionen: 2 206 568)
© Copyright 2024 NORMSERVIS s.r.o.