Standard Practice for Installation and Use of Interior Radiation Control Coating Systems (IRCCS) in Building Construction
Name übersetzen
NORM herausgegeben am 1.3.2020
Bezeichnung normen: ASTM C1321-15(2020)
Ausgabedatum normen: 1.3.2020
SKU: NS-988713
Zahl der Seiten: 3
Gewicht ca.: 9 g (0.02 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
low emittance, paint´high reflectance, paint´high temperature, paint´low emittance, paint´spray-applied, radiation, radiation control coating, radiation control coating´interior ,, ICS Number Code 91.120.10 (Thermal insulation of buildings)
Significance and Use | ||||||||||||||
4.1 This practice recognizes that effectiveness, safety, and durability of an IRCCS depends not only on the quality of the materials, but also on the proper installation. 4.2 Improper installation of an IRCCS will reduce its thermal effectiveness, cause fire risks and other unsafe conditions, and promote deterioration of the structure in which it is installed. Improper installation has the potential to create specific hazards that include: heat buildup in recessed lighting fixtures, deterioration of failure of electrical wiring components, and deterioration of wood structures and paint failure due to moisture accumulation. 4.3 This practice provides directions for the installation of IRCCS materials in a safe and effective manner. Actual conditions in existing buildings will vary greatly. 4.4 The user shall consult the manufacturer for application and installation methods. |
||||||||||||||
1. Scope | ||||||||||||||
1.1 This practice has been prepared for use by the designer, specifier, and applicator of Interior Radiation Control Coating Systems (IRCCS) for use in building construction. The scope contains instructions related to the use and installation of IRCCS that are sprayed, rolled, or brush applied. Examples that this practice is intended to address include: (FIG. 1 Typical Residential Use Note 1: Apply IRCCS to cover the exposed roof deck area
including support structure directly connected to the roof deck
(such as purlins, rafters, and top chord of the trusses). The
low-emittance surface of the IRCCS must face the interior of the
attic.
FIG. 2 Typical Industrial, Commercial, and Agricultural Use Note 1: Apply the IRCCS to cover the entire interior surface
area. The low-emittance surface of the IRCCS must face the interior
of the building.
1.2 This practice covers the installation process from pre-installation inspection through post-installation. It does not cover the production of the Interior Radiation Control Coating Materials. 1.3 This practice is not intended to replace the manufacturer's installation instructions, but it shall be used in conjunction with such instructions. This practice is not intended to supersede local, state, or federal codes. 1.4 This practice assumes that the installer possesses a good working knowledge of the application codes and regulations, safety practices, tools, equipment, and methods necessary for the installation of Interior Coating Materials. It also assumes that the installer understands the fundamentals of building construction that affect the installation of an IRCCS. 1.5 When the installation or use of Interior Radiation Control Coating Materials, accessories, and systems pose safety or health problems, the manufacturer shall provide the user appropriate current information regarding any known problems associated with the intended use of the products and shall also provide direction on protective measures to be employed for safe utilization. The user shall establish appropriate safety and health practices and determine the applicability of regulatory requirements prior to use. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |
||||||||||||||
2. Referenced Documents | ||||||||||||||
|
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-09-17 (Zahl der Positionen: 2 350 347)
© Copyright 2024 NORMSERVIS s.r.o.