Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Test Method for Analysis of Urine for Uranium-235 and Uranium-238 Isotopes by Inductively Coupled Plasma-Mass Spectrometry (Withdrawn 2017)
Automatische name übersetzung:
Standard Test Method for Analyse der Urin für Uran-235 und Uran-238-Isotopen durch induktiv gekoppelte Plasma-Massenspektrometrie
NORM herausgegeben am 1.1.2010
Bezeichnung normen: ASTM C1379-10
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.1.2010
SKU: NS-10934
Zahl der Seiten: 5
Gewicht ca.: 15 g (0.03 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
bioassay, inductively coupled plasma-mass spectrometry, total uranium concentration, urine analysis, ICP-MS (inductively-coupled plasma-mass spectrometry), Mass spectrometry--nuclear materials/applications, Total uranium concentration, Uranium concentration, Uranium oxide (U3O8), Urinalysis, ICS Number Code 11.100 (Laboratory medicine)
Significance and Use | ||||||||||
DOE Order 5480.11 and ANSI N13.30 require that internal dose assessments be made as part of the bioassay program for nuclear facility workers. For indirect bioassay of uranium workers, the uranium isotopes must be measured along with the total uranium in urine samples. The RMDA for each uranium isotope is 0.1 pCi/L. This method is applicable for measuring 235U and 238U at the RMDA. Because of extremely low mass concentration (because of the high specific activity), 234U cannot be measured without additional sample preconcentration. Note 2—Column chromatography separations and concentration of 234U using manual or flow-injection preconcentration followed by ICP-MS isotopic determination are described in Test Methods C1310 and C1345. These methods focus on environmental soil sample analysis, but with some development, may be applicable to digested urine samples. The 234U concentration can be calculated based on an enrichment gradient for workers in uranium enrichment plants, and internal dose assessments can be made. Note 3—Use of high resolution ICP-MS may also be used to obtain lower detection limits. |
||||||||||
1. Scope | ||||||||||
1.1 This test method covers the determination of the concentration of uranium-235 and uranium-238 in urine using Inductively Coupled Plasma-Mass Spectrometry. This test method can be used to support uranium facility bioassay programs. 1.2 This method detection limits for 235U and 238U are 6 ng/L. To meet the requirements of ANSI N13.30, the minimum detectable activity (MDA) of each radionuclide measured must be at least 0.1 pCi/L (0.0037 Bq/L). The MDA translates to 47 ng/L for 235U and 300 ng/L for 238U. Uranium– 234 cannot be determined at the MDA with this test method because of its low mass concentration level equivalent to 0.1 pCi/L. 1.3 The digestion and anion separation of urine may not be necessary when uranium concentrations of more than 100 ng/L are present. 1.4 Units—The values stated in picoCurie per liter units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Note 1—Warning: The ICP-MS is a source of intense ultraviolet radiation from the radio frequency induced plasma. Protection from radio frequency radiation and UV radiation is provided by the instrument under normal operation. |
||||||||||
2. Referenced Documents | ||||||||||
|
Historisch
1.3.2011
Historisch
1.11.2009
Historisch
1.12.2011
Historisch
1.12.2011
Historisch
1.11.2013
Historisch
1.11.2009
Bereitstellung von aktuellen Informationen über legislative Vorschriften in der Sammlung der Gesetze bis zum Jahr 1945.
Aktualisierung 2x pro Monat!
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-11-03 (Zahl der Positionen: 2 209 203)
© Copyright 2024 NORMSERVIS s.r.o.