Standard Specification for Storm Drain Resilient Connectors Between Reinforced Concrete Storm Sewer Structures, Pipes, and Laterals (Metric) (Withdrawn 2020)
Name übersetzen
NORM herausgegeben am 1.3.2019
Bezeichnung normen: ASTM C1478M-19
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.3.2019
SKU: NS-939935
Zahl der Seiten: 3
Gewicht ca.: 9 g (0.02 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
design test method, marking, material requirements acceptance criteria, product marking, resilient connector,, ICS Number Code 13.060.30 (Sewage water)
1. Scope | ||||||||||||||||||||||||||||||||
1.1 This specification covers the minimum performance and material requirements for resilient connectors used for connections between precast reinforced concrete storm sewer structures conforming to Specification C478 and pipes, and between precast reinforced concrete pipe and laterals for storm drainage systems. 1.1.1 These connectors are designed to prevent soil migration between the pipe and storm sewer structure, and between the pipe and lateral. 1.2 This specification is the SI companion to C1478. Note 1: This specification covers the design, material, and
performance of the resilient connection only. Connections covered
by this specification are adequate for hydrostatic pressures up to
41 kPa (4.3 m) without leakage when tested in accordance with
Section 7. Infiltration
quantities for an installed system are dependent upon many factors
other than the connections between storm sewer structures and pipe,
and allowable quantities must be covered by other specifications
and suitable testing of the installed pipeline and
system.
Note 2: For installations that exceed 41 kPa (4.3 m), the user
is cautioned to verify the amount of hydrostatic head pressure the
connector will experience. If the total pressure applied to the
connector exceeds the 41 kPa limits of the specification, the user
is advised to contact the connector manufacturer for alternative
methods of connecting the pipe, or applicable alternative
standards.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |
||||||||||||||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||||||||||||||
|
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-09-28 (Zahl der Positionen: 2 350 600)
© Copyright 2024 NORMSERVIS s.r.o.