Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Guide for Measuring the Reactivity of Hydraulic Refractory Castables using Exothermic Profile
Automatische name übersetzung:
Standard-Leitfaden zur Messung der Reaktivität von Hydraulikfeuerbetone mit Exotherme Profil
NORM herausgegeben am 1.4.2013
Bezeichnung normen: ASTM C1656-13
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.4.2013
SKU: NS-12129
Zahl der Seiten: 3
Gewicht ca.: 9 g (0.02 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
castable, refractory, exothermic profile, EP, working time, ICS Number Code 91.100.10 (Cement. Gypsum. Lime. Mortar)
Significance and Use | ||||||
4.1 The heat of hydration of a calcium aluminate based castable is liberated over a short period of time (as compared to Portland cement). This makes it easy to measure the heat profile using off-the-shelf thermocouple equipment. 4.2 The heat profile can be used to make inferences about the setting and strength gain behavior of a castable and sometimes the working time of a castable. 4.3 Factors that should be controlled when comparing two castables include: size, shape and mass of cast object, start temperature of the mix, temperature of environment, and the thermal conductivity of the environment. If these factors are held constant, then the two castables heat profiles can be compared. 4.4 The temperature increase created by the castable exothermic reaction shall be at least 2.0°C more than the normal fluctuation of the laboratory temperature so that the time of this increase is easily discernible to the user. 4.5 Varying the amount of cement in the castable, the amount of water, the type and quantity of admixtures, and so forth, will change the shape, maximum temperature and time to maximum temperature of the curve. 4.6 Following is an example of a curve generated for an LCC (see Fig. 1) that does exhibit two peaks, the first one marking the end of working time. In this curve one could also infer that the start temperature of the mix was 24°C and also that the hydraulic strength gain reaction was significantly started, but not completed by 6 h. |
||||||
1. Scope | ||||||
1.1 This guide applies to all castables with a reactive binder system that produces a measurable heat profile during the setting and hardening process. The majority of these systems will have calcium aluminate cement as one component of the binder system. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use . |
||||||
2. Referenced Documents | ||||||
|
Historisch
1.11.2009
Historisch
15.2.2009
Historisch
1.6.2011
Historisch
15.12.2013
Historisch
1.8.2011
Historisch
1.6.2012
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-11-04 (Zahl der Positionen: 2 209 323)
© Copyright 2024 NORMSERVIS s.r.o.