Standard Test Method for CBR (California Bearing Ratio) of Laboratory-Compacted Soils (Includes all amendments And changes 1/21/2015).
Automatische name übersetzung:
Standardtestverfahren für CBR (California Bearing Ratio ) des Labor verdichteten Böden
NORM herausgegeben am 15.11.2007
Bezeichnung normen: ASTM D1883-07e2
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 15.11.2007
SKU: NS-18657
Zahl der Seiten: 9
Gewicht ca.: 27 g (0.06 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
Bearing ratio, California bearing ratio (CBR), Compression testing-soil, Earthwork, Foundation investigations, Loading tests-soil, Pavement surfaces, Penetration-soil, Recycled (paving) materials, Roadways, Soil-cohesionless, Soil-penetration, Soil-aggregate, Strength, Subbase, California bearing ratio of laboratory-compacted soils (pavement, subgrade/subbase/course materials), test, ICS Number Code 93.020 (Earth works. Excavations. Foundation construction. Underground works)
1. Scope | ||||||||||||||||||||||||||||||
1.1 This test method covers the determination of the CBR (California Bearing Ratio) of pavement subgrade, subbase, and base course materials from laboratory compacted specimens. The test method is primarily intended for (but not limited to) evaluating the strength of materials having maximum particle sizes less than 3/4 in. (19 mm). 1.2 When materials having maximum particle sizes greater than 3/4 in. (19 mm) are to be tested, this test method provides for modifying the gradation of the material so that the material used for tests all passes the 3/ 4-in. sieve while the total gravel (+No. 4 to 3 in.) fraction remains the same. While traditionally this method of specimen preparation has been used to avoid the error inherent in testing materials containing large particles in the CBR test apparatus, the modified material may have significantly different strength properties than the original material. However, a large experience base has developed using this test method for materials for which the gradation has been modified, and satisfactory design methods are in use based on the results of tests using this procedure. 1.3 Past practice has shown that CBR results for those materials having substantial percentages of particles retained on the No. 4 sieve are more variable than for finer materials. Consequently, more trials may be required for these materials to establish a reliable CBR. 1.4 This test method provides for the determination of the CBR of a material at optimum water content or a range of water content from a specified compaction test and a specified dry unit weight. The dry unit weight is usually given as a percentage of maximum dry unit weight determined by Test Methods D 698 or D 1557. 1.5 The agency requesting the test shall specify the water content or range of water content and the dry unit weight for which the CBR is desired. 1.6 Unless specified otherwise by the requesting agency, or unless it has been shown to have no effect on test results for the material being tested, all specimens shall be soaked prior to penetration. 1.7 For the determination of CBR of field compacted materials, see Test Method D 4429. 1.8 The values stated in inch-pound units are to be regarded as the standard. The SI equivalents shown in parentheses may be approximate. 1.9 All observed and calculated values shall conform to the guidelines for significant digits and rounding established in Practice D 6026. 1.9.1 The procedures used to specify how data are collected, recorded or calculated in this standard are regarded as the industry standard. In addition they are representative of the significant digits that generally should be retained. The procedures used do not consider material variation, purpose for obtaining the data, special purpose studies, or any considerations for the users objectives, and it is common practice to increase or reduce significant digits or reported data to be commensurate with these considerations. It is beyond the scope of this standard to consider significant digits used in analytical methods for engineering design. 1.10 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||||||||||||
|
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-11-22 (Zahl der Positionen: 2 206 568)
© Copyright 2024 NORMSERVIS s.r.o.