Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Test Method for Ignition Characteristics of Finished Textile Floor Covering Materials
Name übersetzen
NORM herausgegeben am 15.3.2021
Bezeichnung normen: ASTM D2859-16(2021)
Ausgabedatum normen: 15.3.2021
SKU: NS-1020818
Zahl der Seiten: 4
Gewicht ca.: 12 g (0.03 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Ignitability and burning behaviour of materials and productsTextile floor coverings
Keywords:
carpet, ignition , pile floor coverings,, ICS Number Code 13.220.40 (Ignitability and burning behaviour of materials and products),59.080.60 (Textile floor coverings)
Significance and Use | ||||||||||||||||
5.1?This test method provides a procedure for identification of those finished textile floor covering materials that can be rated as flame-resistant under specific controlled laboratory conditions. 5.2?This test method does not specify the use of an underlay material. If an underlay material is used to assess the effect of a specific underlay in combination with a specific floor covering, such a variation in procedure must be noted in the report. 5.3?In this test, results are observed with the specimens in a horizontal plane. Different results are possible if the same material is tested or used in any other plane. 5.4?Test Method D2859 for testing finished textile floor covering materials for flammability is considered satisfactory for acceptance testing of commercial shipments since the method has been used extensively in the trade for acceptance testing. In cases of disagreement arising from differences in values reported by the purchaser and the seller when using this method for acceptance testing, the statistical bias, if any, between the laboratory of the purchaser and the laboratory of the seller shall be determined with each comparison being based on testing specimens randomly drawn from one sample of material of the type being evaluated. 5.5?The test procedures of this standard are similar but not identical to those contained in the standards for the surface flammability of carpets and rugs of the U.S. Consumer Product Safety Commission5.6?The acceptance criterion of this test method is consistent with that of CPSC standards (see Section 10). |
||||||||||||||||
1. Scope | ||||||||||||||||
1.1?This fire-test-response standard describes a test method for the determination of the flammability of finished textile floor covering materials when exposed to an ignition source under controlled laboratory conditions. 1.1.1?Carpets and rugs offered for sale in the United States are required by the Consumer Product Safety Commission (CPSC) to comply with the test methods in 16 CFR 1630 or 16 CFR 1631, as appropriate. 1.1.2?This test method is similar but not identical to the test methods contained in 16 CFR 1630 and CFR 1631 and issued by CPSC. If compliance with one of the CPSC test methods is required, this test method does not ensure regulatory compliance. 1.2?This test method is applicable to all types of textile floor coverings, regardless of the method of fabrication or whether they are made from natural or man-made fibers. It is possible to apply this test method to unfinished material; however, the results of such a test shall not be considered a satisfactory evaluation of a textile floor covering material for ultimate consumer use. 1.3?The values stated in SI units are to be regarded as standard. The values given in parentheses after SI units are provided for information only and are not considered standard. 1.4?This standard is used to measure and describe the response of materials, products, or assemblies to heat and flame under controlled conditions, but does not by itself incorporate all factors required for fire hazard or fire risk assessment of the materials, products, or assemblies under actual fire conditions. 1.5?Fire testing of products and materials is inherently hazardous, and adequate safeguards for personnel and property shall be employed in conducting these tests 1.6?The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard. 1.7?This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.8?This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |
||||||||||||||||
2. Referenced Documents | ||||||||||||||||
|
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-11-04 (Zahl der Positionen: 2 209 323)
© Copyright 2024 NORMSERVIS s.r.o.