Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Test Method for Separation and Collection of Particulate and Water-Soluble Gaseous Fluorides in the Atmosphere (Filter and Impinger Method)
Automatische name übersetzung:
Standard Test Method for Trennung und Sammlung der Partikel und wasserlösliche gasförmige Fluoride in der Atmosphäre (Filter und Impinger-Verfahren)
NORM herausgegeben am 1.4.2012
Bezeichnung normen: ASTM D3267-12
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.4.2012
SKU: NS-23082
Zahl der Seiten: 6
Gewicht ca.: 18 g (0.04 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
ambient atmospheres, fluorides, gaseous fluorides, particulate fluorides, sampling , Atmospheric analysis--fluoride isolation/analysis, Automated procedures--atmospheric analysis, Continuous separation/collection, Filters/filter procedures--atmospheric analysis, Fluoride content--atmosphere/plant tissues, Particulate gaseous fluorides--atmospheric, Separation and collection--atmospheric analysis, ICS Number Code 13.040.20 (Ambient atmospheres)
Significance and Use | ||||||||||||||||||
This test method provides a means of separation and collection of particulate and water soluble gaseous fluoride and provides samples that are convenient to analyze. |
||||||||||||||||||
1. Scope | ||||||||||||||||||
1.1 This test method provides a procedure for separation and collection on a chemically treated filter and in an impinger of particulate and water-soluble gaseous fluoride in the atmosphere. The sampling rate may vary from 30 L/min (1.0 ft3/min) to 15 L/min (0.5 ft3/min) for longer sampling periods depending on the atmospheric fluoride concentration. This test method is not intended to be applied to gaseous fluorine compounds that are not water-soluble 1.2 There are several limitations of the test method: 1.2.1 Although the acid-treated, medium retentive, prefilter has been shown to allow passage of HF, it will restrict passage of particulate matter only as small as about 1 μm. Thus, smaller particulate matter may pass through the filter and be collected in or pass through the impingers. 1.2.2 The maximum sample volume to be taken using this test method prior to changing the acid-treated prefilter is recommended as 12 m3. This recommendation is made to minimize any effects due to particulate matter build-up. 1.3 The values stated in SI units are to be regarded as the standard. The inch-pound units given in parentheses are for information only. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.For specific precautionary statements, see 7.2 and 7.4.6. |
||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||
|
Historisch
1.4.2014
Historisch
1.10.2012
Historisch
1.4.2008
Historisch
1.4.2013
Historisch
1.12.2013
Historisch
1.4.2012
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-12-21 (Zahl der Positionen: 2 216 840)
© Copyright 2024 NORMSERVIS s.r.o.