Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Test Method for Anions in Water by Chemically Suppressed Ion Chromatography
Automatische name übersetzung:
Standard Test Method for Anionen in Wasser durch chemische Suppressions-Ionenchromatographie
NORM herausgegeben am 1.1.1991
Bezeichnung normen: ASTM D4327-97
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.1.1991
SKU: NS-26855
Zahl der Seiten: 8
Gewicht ca.: 24 g (0.05 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
anions, drinking water, ion chromatography, reagent water, waste water, ICS Number Code 13.060.50 (Examination of water for chemical substances)
1. Scope | ||||||||||||||
1.1 This test method covers the sequential determination of fluoride, chloride, nitrite, ortho -phosphate, bromide, nitrate, and sulfate ions in water by chemically suppressed ion chromatography. Note 1-Order of elution is dependent upon the column used; see Fig. 1.1.2 This test method is applicable to drinking and waste waters. The ranges tested for this test method for each anion were as follows (measured in mg/L): Fluoride 0.26 to 8.49 Chloride 0.78 to 26.0 Nitrite-N 0.36 to 12.0 Bromide 0.63 to 21.0 Nitrate-N 0.42 to 14.0 o-Phosphate 0.69 to 23.1 Sulfate 2.85 to 95.01.3 It is the user's responsibility to ensure the validity of this test method for other matrices. 1.4 Concentrations as low as 0.01 mg/L were determined depending upon the anions to be quantitated, in single laboratory work. Utilizing a 50-[mu]L sample volume loop and a sensitivity of 3 [mu]S/cm full scale, the approximate detection limits shown in Table 1 can be achieved. If lower detection levels are required, the sensitivity may be improved by using a lower scale setting (<3 [mu]S/cm) or a larger sample injection loop (>100 [mu]L). The analyst must assure optimum instrument performance to maintain a stable baseline at more sensitive conductivity full-scale settings. 1.5 The upper limit of this test method is dependent upon total anion concentration and may be determined experimentally as described in Annex A1. These limits may be extended by appropriate dilution or by use of a smaller injection volume. 1.6 Using alternate separator column and eluents may permit additional anions such as formate or citrate to be determined. This is not the subject of this test method. 1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||
2. Referenced Documents | ||||||||||||||
|
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-11-22 (Zahl der Positionen: 2 206 568)
© Copyright 2024 NORMSERVIS s.r.o.