Standard Test Method for Measurement of Transition Temperatures of Petroleum Waxes by Differential Scanning Calorimetry (DSC)
Automatische name übersetzung:
Standard Test Method for Messung der Übergangstemperaturen von Erdölwachsen durch Differential Scanning Calorimetry (DSC)
NORM herausgegeben am 1.4.2015
Bezeichnung normen: ASTM D4419-90(2015)
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.4.2015
SKU: NS-588676
Zahl der Seiten: 4
Gewicht ca.: 12 g (0.03 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
differential scanning calorimetry, petroleum wax, thermal properties, transition temperature ,, ICS Number Code 75.140 (Waxes, bituminous materials and other petroleum products)
Significance and Use | ||||||||||||
5.1 DSC in a convenient and rapid method for determining the temperature limits within which a wax undergoes during transitions. The highest temperature transition is a solid-liquid transition associated with complete melting; it can guide the choice of wax storage and application temperatures. The solid-solid temperature transition is related to the properties of the solid, that is, hardness and blocking temperature. Note 2: For a relatively narrow cut petroleum wax, the lowest
transition will be a solid-solid transition. A narrow cut wax is
one obtained by deoiling a single petroleum distillate with a
maximum range of 120 °F between its 5 % and 95 % vol in accordance
with Test Method D1160
boiling points (converted to 760 torr). The DSC method cannot
differentiate between solid-liquid and solid-solid transitions.
Such information must be predetermined by other techniques. In the
case of blends, the lower temperature transition may be envelopes
of both solid-liquid and solid-solid transitions.
5.2 Since petroleum wax is a mixture of hydrocarbons with different molecular weights, its transitions occur over a temperature range. This range is one factor that influences the width, expressed in °C, of the DSC peaks. The highest temperature transition is a first-order transition. If, for a series of waxes, there is supporting evidence that the highest temperature transition of each wax is the major first-order transition, its relative width should correlate with the relative width of the wax's molecular weight distribution. |
||||||||||||
1. Scope | ||||||||||||
1.1 This test method covers the transition temperatures of petroleum waxes, including microcrystalline waxes, by differential scanning calorimetry (DSC). These transitions may occur as a solid-solid transition or as a solid-liquid transition. 1.2 The normal operating temperature range extends from 15 °C to 150 °C (Note 1). 1.3 The values stated in SI units are to be regarded as the standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||
2. Referenced Documents | ||||||||||||
|
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2025-04-28 (Zahl der Positionen: 2 197 482)
© Copyright 2025 NORMSERVIS s.r.o.