Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Practice for Maintaining Constant Relative Humidity by Means of Aqueous Glycerin Solutions
Automatische name übersetzung:
Standard Praxis für eine konstante relative Luftfeuchtigkeit mittels wässriger Lösungen Glycerin
NORM herausgegeben am 1.8.2011
Bezeichnung normen: ASTM D5032-11
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.8.2011
SKU: NS-29580
Zahl der Seiten: 3
Gewicht ca.: 9 g (0.02 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Ventilation and air-conditioning systemsGeology. Meteorology. Hydrology
Keywords:
aqueous glycerin solutions, conditioning, constant relative humidity, glycerin, relative humidity: Aqueous solutions, Atmospheres--conditioning/testing, Conditioning--electrical insulating materials, Constant relafive humidity, Contamination prevention, Controlled testing conditions/environments, Dielectric breakdown voltage, Dielectric properties/testing, Glycerin, Permittivity (dielectric constant), Relative humidity (RH), Temperature tests--room
Significance and Use | ||||||||||
Controlled relative humidity environments are important for conditioning materials for shelf-life studies or for investigating the change in physical or dielectric properties after exposure. The use of aqueous-glycerin solutions reduces the possibility of contamination of the materials or corrosion of electrode systems which would be more likely to result from saturated salt or acid water solutions. Applicable material specifications should state the exposure conditions, including time, temperature and relative humidity that a material should be subjected to before subsequent testing. Typical conditions are given in Practice D618 or D6054. |
||||||||||
1. Scope | ||||||||||
1.1 This practice describes a method for obtaining constant relative humidity ranging from 30 to 98 % at temperatures ranging from 0 to 70°C in relatively small containers by means of an aqueous glycerin solution. 1.2 This practice is applicable for closed systems such as environmental conditioning containers. 1.3 This practice is not recommended for the generation of continuous (flowing) streams of constant humidity unless precautionary criteria are followed to ensure source stability. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||
2. Referenced Documents | ||||||||||
|
Historisch
1.8.2013
Historisch
1.5.2014
Historisch
15.1.2010
Historisch
1.10.2013
Historisch
1.8.2012
Historisch
1.1.2012
Letzte Aktualisierung: 2024-11-01 (Zahl der Positionen: 2 208 817)
© Copyright 2024 NORMSERVIS s.r.o.