Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Test Method for (Analytical Procedure for) Analyzing the Effects of Partial Penetration of Control Well and Determining the Horizontal and Vertical Hydraulic Conductivity in a Nonleaky Confined Aquifer (Withdrawn 2015)
Automatische name übersetzung:
Standard Test Method for (Analytische Vorgehensweise) die Analyse der Auswirkungen von Teil Penetration of Control Gut und Bestimmung der horizontalen und vertikalen hydraulischen Leitfähigkeit in einem Nonleaky gespannten Grundwasserleiter
NORM herausgegeben am 1.10.2006
Bezeichnung normen: ASTM D5473-93(2006)
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.10.2006
SKU: NS-31366
Zahl der Seiten: 17
Gewicht ca.: 51 g (0.11 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
anistroph, aquifers, aquifer tests, control wells, groundwater, hydraulic conductivity, observation wells, storage coefficient, transmissivity: Anisotropy, Aquifers, Artesian well, Control wells, Ground-water monitoring/sampling, Horizontal hydraulic conductivity, Hydraulic conductivity/transmissivity, Nonleaky confined aquifer, Observation wells, Storage--aquifers, Transmissivity, ICS Number Code 13.060.10 (Water of natural resources)
Significance and Use | ||||||
Assumptions: Control well discharges at a constant rate, Q. Control well is of infinitesimal diameter and partially penetrates the aquifer. The nonleaky artesian aquifer is homogeneous, and aerially extensive. The aquifer may also be anisotropic and, if so, the directions of maximum and minimum hydraulic conductivity are horizontal and vertical, respectively. The methods may be used to analyze tests on unconfined aquifers under conditions described in a following section. Discharge from the well is derived exclusively from storage in the aquifer. The geometry of the assumed aquifer and well conditions are shown in Fig. 2. Implications of Assumptions—The vertical
flow components in the aquifer are induced by a control well that
partially penetrates the aquifer, that is, a well that is not open
to the aquifer through its full thickness. The effects of vertical
flow components are measured in piezometers near the control well,
that is, within a distance, r, in which
vertical flow components are significant, that is: Application of Method to Unconfined Aquifers: Although the assumptions are applicable
to artesian or confined conditions, Weeks (1) has pointed out that the solution may be applied
to unconfined aquifers if drawdown is small compared with the
saturated thickness of the aquifer or if the drawdown is corrected
for reduction in thickness of the aquifer, and the effects of
delayed gravity response are small. The effects of gravity response
become negligible after a time as given, for piezometers near the
water table, by the equation: for values of ar/b < 0.4 and by
the equation: for greater values of ar/b. Drawdown in an unconfined aquifer is also affected by curvature of the water table or free surface near the control well, and by the decrease in saturated thickness, that causes the transmissivity to decline toward the control well. This test method should be applicable to analysis of tests on water-table aquifers for which the control well is cased to a depth below the pumping level and the drawdown in the control well is less than 0.2b. Moreover, little error would be introduced by effects of water-table curvature, even for a greater drawdown in the control well, if the term (s2/2 b) for a given piezometer is small compared to the δ s term. The transmissivity decreases as a result
of decreasing thickness of the unconfined aquifer near the control
well. Jacob (4) has shown that the effect
of decreasing transmissivity on the drawdown may be corrected by
the equation: where s is the observed drawdown and s′ is the drawdown in an equivalent confined aquifer. |
||||||
1. Scope | ||||||
1.1 This test method covers an analytical solution for determining the horizontal and vertical hydraulic conductivity of an aquifer by analysis of the response of water levels in the aquifer to the discharge from a well that partially penetrates the aquifer. 1.2 Limitations—The limitations of the technique for determination of the horizontal and vertical hydraulic conductivity of aquifers are primarily related to the correspondence between the field situation and the simplifying assumption of this test method. 1.3 The values stated in either inch-pound or SI units are to be regarded separately as the standard. The values given in parentheses are for information only. 1.4 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||
2. Referenced Documents | ||||||
|
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2025-04-27 (Zahl der Positionen: 2 197 486)
© Copyright 2025 NORMSERVIS s.r.o.