Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Test Method for Resistance to Bending of Paper of Low Bending Stiffness (Taber-Type Tester in 0 to 10 Taber Stiffness Unit Configuration)
Automatische name übersetzung:
Standard Test Method for Biegefestigkeit von Papier mit geringer Biegesteifigkeit ( Taber - Typ Tester in 0 bis 10 Taber-Steifigkeitsgerätekonfiguration)
NORM herausgegeben am 10.12.1997
Bezeichnung normen: ASTM D5650-97
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 10.12.1997
SKU: NS-32036
Zahl der Seiten: 4
Gewicht ca.: 12 g (0.03 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
Bending resistance, Cut-sized papers, Flexible paper, Low-bending stiffness, Low grammage paper, Paper, Resistance to bending, Stiffness, Taber tester, bending resistance-paper of low-bending stiffness, using taber-type, tester in 0-10 stiffness unit configuration, test
1. Scope | ||||||||||
1.1 This test method covers a procedure used to measure the resistance to bending of papers which are of low grammage or high flexibility, or both, and which exhibit bending stiffness in the range from 0 to 10 Taber stiffness units. 1.2 The bending moment required to deflect the free end of a 38-mm (1.5-in.) wide vertically clamped specimen 15° from its center line when the load is applied 10 mm (0.39 in.) away from the clamp is determined. The resistance to bending is calculated from the bending moment. 1.3 The instrument used in this test method is identical to that described in Test Method D5342, used in the modified configuration described in Section 9. 1.4 Test results obtained using the Taber-Type tester as described in this test method have been reported to be as much as 40% different from those obtained using Test Method D5342, and this test method shall not be used where Test Method D5342 is specified. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||
2. Referenced Documents | ||||||||||
|
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-11-21 (Zahl der Positionen: 2 206 478)
© Copyright 2024 NORMSERVIS s.r.o.