Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Guide for Selection of Soil and Rock Sampling Devices Used With Drill Rigs for Environmental Investigations
Automatische name übersetzung:
Standard-Leitfaden für die Auswahl der Boden- und Felsprobenehmer Verwendet mit Bohrgeräte für Umweltuntersuchungen
NORM herausgegeben am 1.8.2013
Bezeichnung normen: ASTM D6169/D6169M-13
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.8.2013
SKU: NS-34082
Zahl der Seiten: 20
Gewicht ca.: 60 g (0.13 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Other standards related to soil qualityOther mining equipment
Keywords:
drilling, environmental site characterization, exploration, feasibility studies, field investigations, geological investigations, groundwater, hydrologic investigations, reconnaissance surveys, sampling, site characterization, site investigations, soil surveys, subsurface investigations, ICS Number Code 13.080.99 (Other standards related to soil quality),73.100.99 (Other mining equipment)
Significance and Use | ||||||||||||||||||||||||||||||||||||||||||||||||||||
4.1 Direct observation of the subsurface by the collection of soil and rock samples is an essential part of site characterization for environmental purposes (see 7.1.7 of Guide D5730). This guide provides information on the major types of soil and rock sampling devices used on drill rigs to assist in selection of devices that are suitable for known site geologic conditions, and provide samples that meet project objectives. This guide should not be used as a substitute for consulting with someone experienced in sampling soil or rock in similar formations before determining the best method and type of sampling. 4.2 This guide should be used in conjunction with Guides D2113 and D6151 and drilling method-specific guides (see Guides D5781, D5782, D5783, D5784, D5872, D5875 and D5876) as part of developing a detailed site investigation and sampling plan (see 5.1.5 of Guide D5730) for sites that require mobilization of a drill rig for subsurface investigations. The selection of drilling methods and sampling devices goes hand-in-hand. In some cases soil sample requirements may influence choice of drilling method, or conversely, types of available drill rigs may influence choice of sampling devices. 4.3 This guide should be used in conjunction with Guide D5434 for field logging of soil and rock samples, Practice D5911 for data elements to identify a soil sampling site, and where appropriate, Practice D4220, for preserving and transporting soil samples, Practice D5070 for preserving and transporting rock core samples, Practice D3694 for preparation of sample containers and for preservation of organic constituents, and Practice D5088 for decontamination of field equipment used at waste sites. 1.1 This guide covers guidance for
the selection of soil and rock sampling devices used with drill
rigs for the purpose of characterizing in situ physical and
hydraulic properties, chemical characteristics, subsurface
lithology, stratigraphy and structure, and hydrogeologic units in
environmental investigations.
1.2 This guide does not specifically address selection of soil sampling devices for use with direct-push sampling systems, but the information in this guide on thick-wall and thin-wall samplers is generally applicable to direct-push soil sampling. 1.3 This guide should be used in conjunction with referenced ASTM guides, practices, and methods on drilling techniques for geoenvironmental investigations and use of sampling devices referenced in 2.1, and with Guide D5730. 1.4 This guide does not address selection of sampling devices for hand-held soil sampling equipment, and soil sample collection with solid-stem augering devices, or collection of grab samples or hand-carved block samples from accessible excavations. Refer to Appendix X1.2 for guidance on these topics. This guide should be used in conjunction with Guide D4700 when thin-walled, split barrel, ring-lined barrel and piston samplers with solid- and hollow-stem augers are used in the unsaturated zone. 1.5 This guide does not address devices for collecting cores from submerged sediments or sampling devices for solid wastes. Refer to Guide D4823 for guidance on these topics. 1.6 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. 1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. 1.8 This guide offers an organized collection of information or series of options and does not recommend a specific course of action. This document cannot replace education and experience and should be used in conjunction with professional judgment. The word “Standard” in the title of this document means that the document has been approved through the ASTM consensus process. |
||||||||||||||||||||||||||||||||||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Historisch
15.1.2013
Historisch
1.5.2014
Historisch
1.9.2012
Historisch
1.5.2011
Historisch
1.11.2011
Historisch
1.11.2012
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-11-01 (Zahl der Positionen: 2 208 817)
© Copyright 2024 NORMSERVIS s.r.o.