Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Test Method for Peel Adhesion of Pressure-Sensitive Label Stocks at a 90° Angle
Automatische name übersetzung:
Standard Test Method for Peel Adhesion of Pressure-Sensitive Etikettenmaterialien in einem 90 ° -Winkel
NORM herausgegeben am 1.4.2011
Bezeichnung normen: ASTM D6252/D6252M-98(2011)
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.4.2011
SKU: NS-34404
Zahl der Seiten: 3
Gewicht ca.: 9 g (0.02 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
label stock, peel adhesion at 90° angle, pressure-sensitive label stock, Labels/labeling, Peel adhesion, Pressure-sensitive materials/applications, Quality assurance (QA), ICS Number Code 83.180 (Adhesives)
Significance and Use | ||||||||||
This test method is a tool for quality assurance use. Given a pressure-sensitive label stock and a requirement in terms of the minimum or maximum peel adhesion value expected for this label stock, the data from the test can be used in conjunction with acceptance criteria. This test method can show the relative bond strength of a given label stock to one or more surfaces of varied material and texture as compared to the standard stainless steel panel. Substitution of panels representative of the proposed substrates for the standard stainless steel panel would be acceptable for this procedure. |
||||||||||
1. Scope | ||||||||||
1.1 This test method covers the measurement of the peel adhesion of pressure-sensitive label stocks. This test method gives a measure of the adherence to a standard steel substrate or to other surfaces of interest for a pressure-sensitive label stock. 1.2 This test method provides a means of assessing the uniformity of the adhesion of a given type of pressure-sensitive label stock. The assessment may be within a sheet or roll, between sheets or rolls, or between production lots. 1.3 Variations in the label stock facestock and adhesive can affect the response; therefore, this test method cannot be used to pinpoint the specific cause(s) of nonuniformity. 1.4 This test method may not be appropriate to test label stocks having either stiff backings or backings showing a high stretch at low forces. These characteristics could result in a high variability of the test response, which is not a true indication of the real nature of the adhesive bond. 1.5 The values stated in either SI or inch-pound units are to be regarded separately as the standard. The values stated in each system may not be exact equivalents; therefore, each system must be used independently, without combining values in any way. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||
2. Referenced Documents | ||||||||||
|
Historisch
1.10.2013
Historisch
1.1.2011
Historisch
1.10.2012
Historisch
1.5.2012
Historisch
1.7.2013
Historisch
1.10.2013
Bereitstellung von aktuellen Informationen über legislative Vorschriften in der Sammlung der Gesetze bis zum Jahr 1945.
Aktualisierung 2x pro Monat!
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-11-29 (Zahl der Positionen: 2 209 787)
© Copyright 2024 NORMSERVIS s.r.o.