Standard Test Method for Color Determination of Plastic Pellets
Automatische name übersetzung:
Standardtestverfahren für Farbbestimmung von Kunststoffgranulat
NORM herausgegeben am 1.11.2013
Bezeichnung normen: ASTM D6290-13
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.11.2013
SKU: NS-34544
Zahl der Seiten: 5
Gewicht ca.: 15 g (0.03 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
color, pellets, plastics, yellowness, yellowness index, ICS Number Code 17.180.20 (Colours and measurement of light), 83.080.01 (Plastics in general)
Significance and Use | ||||||||||||||||||||
4.1 Before proceeding with this test method, make reference should be made to the specification of the material being tested. Any test specimen preparation, conditioning, dimensions, or testing parameters, or a combination thereof, covered in the materials specification shall take precedence over those mentioned in this test method. If there are no material specifications, then default conditions apply. 4.2 This test method describes a
technique useful for making color comparisons of resins in pellet
form that is fast and convenient as it does not require
preparation, such as molding or extruding specimens. The test
method shall be used only to compare specimens of similar pellet
shape, size, texture, and degree of translucency. For example,
compare translucent disc-shaped pellets to translucent disc-shaped
pellets, not with opaque, rectangular shaped pellets.
4.3 Exact measurements of resin pellet color are not necessarily directly related to the color of the final cast, molded or extruded product due to the multitude of variables, such as producing variables, methods, and pellet shape and size. Color measurements can be useful for comparing resins in pellet form when all samples are similar in shape and size. 4.4 A three-number tristimulus system is necessary to quantify color completely and precisely. The general method used in this procedure measures color using the CIE Systems described in Practice E308, Test Method D2244, the CIE 1976 (X, Y, Z) system, and, the CIELAB 1976 color space.3 4.5 Individual components of the tristimulus measurement such as CIE Y (Luminance), Hunter L, a, b, or CIE L*, a*, b* values or other useful metrics like yellowness index can be used to describe color attributes of materials. This test method describes a standard procedure on how these measurements are made. |
||||||||||||||||||||
1. Scope | ||||||||||||||||||||
1.1 This test method is intended primarily for the instrumental measurement of the degree of yellowness (or change of degree of yellowness) under daylight illumination of homogeneous, nonfluorescent, nearly-colorless transparent or nearly-white translucent or opaque plastics. The measurement is made on pellets and based on tristimulus values obtained with a spectrophotometer or colorimeter. 1.2 This test method is applicable to the color analysis of plastic pellets. It is possible that each material will have unique characteristics that determine the color values. 1.3 This procedure outlines a method to determine color measurements, such as Yellowness Index, CIE X, Y, Z, and Hunter L, a, b, or CIE L*, a*, b*. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
|
|
Standard Terminology Relating to Plastics
|
|
Standard Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method
|
|
Standard Practice for Calculating Yellowness and Whiteness Indices from Instrumentally Measured Color Coordinates
|
|
Standard Practice for Computing the Colors of Objects by Using the CIE System
|
|
Standard Terminology of Appearance
|
|
Standard Guide for Selection of Geometric Conditions for Measurement of Reflection and Transmission Properties of Materials
|
|
Standard Practice for Calculation of Color Tolerances and Color Differences from Instrumentally Measured Color Coordinates
|
|
Standard Test Method for Reflectance Factor and Color by Spectrophotometry Using Hemispherical Geometry
|
|
Standard Test Method for Reflectance Factor and Color by Spectrophotometry Using Bidirectional (45?:0? or 0?:45?) Geometry
|
|
Standard Test Method for Color and Color-Difference Measurement by Tristimulus Colorimetry |
Historisch
1.4.2012
Historisch
1.7.2012
Historisch
1.7.2012
Historisch
1.1.2014
Historisch
1.4.2012
Historisch
1.11.2011
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-11-21 (Zahl der Positionen: 2 206 478)
© Copyright 2024 NORMSERVIS s.r.o.