Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Test Method for Analysis of Toluene by Capillary Column Gas Chromatography (Withdrawn 2018)
Automatische name übersetzung:
Standard Test Method for Analysis von Toluol durch KAPILLARGASCHROMATOGRAFISCHE
NORM herausgegeben am 15.3.2012
Bezeichnung normen: ASTM D6526-12
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 15.3.2012
SKU: NS-35496
Zahl der Seiten: 5
Gewicht ca.: 15 g (0.03 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
benzene, gas chromatography, impurities, toluene purity, 1,4-dioxane, Capillary gas chromatography, Chemical analysis--paints/related coatings/materials, 1,4-Dioxane, Gas chromatography (GC)--paints/related coatings/materials, Impurities--organic compounds, Toluene, Toluene purity, ICS Number Code 71.040.50 (Physicochemical methods of analysis), 71.080.15 (Aromatic hydrocarbons)
Significance and Use | ||||||||||||||||||
This test method is suitable for determining the concentrations of known impurities in refined toluene and for use as an integral quality control tool where toluene is produced or used in manufacturing. Toluene purity is reported, but a chromatographic analysis cannot determine absolute purity if unknown or undetected components are present in the sample. |
||||||||||||||||||
1. Scope | ||||||||||||||||||
1.1 This test method covers the determination of hydrocarbon impurities typically found in, and the purity of, samples containing 98 wt % and greater toluene. This test method is applicable to impurity concentrations in the range of 0.0005 to 1.6 wt %. 1.2 Monocyclic aromatic hydrocarbons containing 6 through 8 carbon atoms, cumene, 1,4–dioxane, and nonaromatic aliphatic hydrocarbons containing up to 12 carbon atoms can be detected by this test method. The nonaromatic compounds are determined as a composite. 1.3 The following applies to all specified limits in this test method: for purposes of determining conformance with this test method, an observed value or a calculated value shall be rounded off “to the nearest unit” in the last right-hand digit used in expressing the specification limit, in accordance with the rounding-off method of Practice E29. 1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 9. |
||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||
|