Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Guide for Application of Fully Adhered Hot-Applied Reinforced Waterproofing Systems
Automatische name übersetzung:
Standard-Leitfaden zur Anwendung der vollflächig verklebte Hot-Applied Verstärkte Abdichtungssysteme
NORM herausgegeben am 1.1.2009
Bezeichnung normen: ASTM D6622-01(2009)
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.1.2009
SKU: NS-35927
Zahl der Seiten: 4
Gewicht ca.: 12 g (0.03 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
application, asphalt, coal tar pitch, modified bitumen, polymer-modified bitumen sheet, rubberized asphalt waterproofing, waterproofing, Application--roofing/waterproofing material, Fully-adhered waterproofing systems, Reinforced roofing/waterproofing materials, Waterproofing materials/applications, ICS Number Code 91.100.50 (Binders. Sealing materials)
Significance and Use | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
This guide outlines general procedures and precautions for the application of fully adhered hot-applied built-up reinforced waterproofing systems. This guide is not all inclusive and is intended only to supplement detailed instructions from designers, and the recommendations of manufacturers. Manufacturers of some of the systems addressed by this guide require proprietary products and special procedures not described in this guide. Manufacturers' recommendations should therefore be considered in the application of this guide. For design guidelines, consult Guide C 981. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1. Scope | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1.1 This guide covers the minimum installation recommendations for fully adhered, hot-applied reinforced waterproofing systems on vertical and low-slope (plaza deck) surfaces. 1.2 For the purpose of this guide, the substrate is assumed to be concrete or masonry, structurally sound, able to accept the weight of anticipated loads, and meets the local building code requirements. Similarly, all components of the waterproofing system are assumed to comply with any federal, state, and local environmental regulations that may be in effect at the time of installation. Expansion joints, insulation, drainage layers, and overburden are beyond the scope of this guide. 1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory requirements prior to use. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Historisch
1.6.2010
Historisch
1.4.2014
Historisch
1.6.2012
Historisch
1.7.2007
Historisch
1.6.2014
Historisch
15.8.2011
Bereitstellung von aktuellen Informationen über legislative Vorschriften in der Sammlung der Gesetze bis zum Jahr 1945.
Aktualisierung 2x pro Monat!
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-11-04 (Zahl der Positionen: 2 209 323)
© Copyright 2024 NORMSERVIS s.r.o.