Standard Test Method for Determining Connection Strength Between Geosynthetic Reinforcement and Segmental Concrete Units (Modular Concrete Blocks)
Automatische name übersetzung:
Standard Test Methode zur Bestimmung der Kraft Verbindung zwischen Geokunststoffbewehrung und Segmentbeton Units (Modular Concrete Blocks)
NORM herausgegeben am 1.6.2011
Bezeichnung normen: ASTM D6638-11
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.6.2011
SKU: NS-35973
Zahl der Seiten: 7
Gewicht ca.: 21 g (0.05 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
connections, geogrid, geosynthetic, geosynthetic reinforcement, geotextile, performance test, segmental concrete units, tensile test, ICS Number Code 91.100.50 (Binders. Sealing materials)
Significance and Use | ||||||||||
The connection strength between geosynthetic reinforcement and segmental concrete block units is used in design of reinforced soil retaining walls. This test is used to determine the connection strength for the design of the connection system formed by segmental concrete block units and geosynthetic reinforcement layers in reinforced soil retaining walls. Performing a series of these connection tests at varying normal loads permits development of a relationship between connection strength and normal load. This relationship may be linear, bi-linear, or some other complex mathematical expression. This connection strength test is meant to be a performance test (laboratory or field), therefore, it should be conducted using full-scale system components. The conditions for the test are selected by the user and are not for routine testing. As a performance test on full-scale system components it accounts for some of the variables in construction procedures and materials tolerance normally present for these types of retaining wall systems. |
||||||||||
1. Scope | ||||||||||
1.1 This test method is used to determine the connection properties between a layer of geosynthetic reinforcement and segmental concrete block units used in construction of reinforced soil retaining walls. The test is carried out under conditions determined by the user that reproduce the connection system at full-scale. The results of a series of tests are used to define a relationship between connection strength for a segmental unit-geosynthetic connection system and normal load. 1.2 This is a performance test used to determine properties for design of retaining wall systems utilizing segmental concrete units and soil reinforcing geosynthetics, either geotextiles or geogrids. The test is performed on a full-scale construction of the connection and may be run in a laboratory or the field. 1.3 The values stated in SI units are regarded as the standard. The values stated in inch-pound units are provided for information only. This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||
2. Referenced Documents | ||||||||||
|
Historisch
1.1.2009
Historisch
1.6.2011
Historisch
1.5.2014
Historisch
15.7.2014
Historisch
1.12.2010
Historisch
1.6.2012
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-12-23 (Zahl der Positionen: 2 217 157)
© Copyright 2024 NORMSERVIS s.r.o.