Standard Test Method for Determination of Turbidity Below 5 NTU in Static Mode
Automatische name übersetzung:
Standard-Testverfahren zur Bestimmung der Trübung unter 5 NTU im statischen Modus
NORM herausgegeben am 1.6.2012
Bezeichnung normen: ASTM D6855-12
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.6.2012
SKU: NS-36782
Zahl der Seiten: 15
Gewicht ca.: 45 g (0.10 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
calibration, calibration turbidity standard, calibration verification, measurement, nephelometric turbidity, ratio turbidity, turbidimeter , turbidity, turbidity standards, ICS Number Code 19.100 (Non-destructive testing)
Significance and Use | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Turbidity is undesirable in drinking water, plant effluent waters, water for food and beverage processing, and for a large number of other water-dependent manufacturing processes. Removal is often accomplished by coagulation, settling, and filtration. Measurement of turbidity provides a rapid means of process control for when, how, and to what extent the water must be treated to meet specifications. This test method is suitable to turbidity such as that found in drinking water, process water, and high purity industrial water. When reporting the measured result, appropriate units should also be reported. The units are reflective of the technology used to generate the result, and if necessary, provide more adequate comparison to historical data sets. Table 1 describes technologies and reporting results (see also Refs (1),(2),(3)). Those technologies listed are appropriate for the range of measurement prescribed in this method. Others may come available in the future. Fig. X5.1 provides a flow chart to aid in selection of the appropriate technology for low-level static turbidity applications. If a design that falls outside of the criteria listed in Table 1 is used, the turbidity should be reported in turbidity units (TU) with a subscripted wavelength value to characterize the light source that was used. TABLE 1 Applicable Technologies Available for Performing Static Turbidity Measurements Below 5 NTU
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1. Scope | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1.1 This test method covers the static determination of turbidity in water (see 4.1). 1.2 This test method is applicable to the measurement of turbidities under 5.0 nephelometric turbidity units (NTU). 1.3 This test method was tested on municipal drinking water, ultra-pure water and low turbidity samples. It is the user's responsibility to ensure the validity of this test method for waters of untested matrices. 1.4 This test method uses calibration standards are defined in NTU values, but other assigned turbidity units are assumed to be equivalent. 1.5 This test method assigns traceable reporting units to the type of respective technology that was used to perform the measurement. Units are numerically equivalent with respect to the calibration standard. For example, a 1.0 NTU formazin standard is also equal to a 1.0 FNU standard, a 1.0 FNRU standard and so forth. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Refer to the MSDSs for all chemicals used in this procedure. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Historisch
1.6.2013
Historisch
1.6.2013
Historisch
1.11.2012
Historisch
1.7.2013
Historisch
1.6.2014
Historisch
1.8.2011
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-11-22 (Zahl der Positionen: 2 206 568)
© Copyright 2024 NORMSERVIS s.r.o.