Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Test Method for Flash Point by Modified Continuously Closed Cup (MCCCFP) Tester (Includes all amendments And changes 7/6/2016).
Automatische name übersetzung:
Standardtestverfahren für Flammpunkt von Modified Kontinuierlich Geschlossen Cup (MCCCFP) Tester
NORM herausgegeben am 1.12.2012
Bezeichnung normen: ASTM D7094-12e1
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.12.2012
SKU: NS-37527
Zahl der Seiten: 8
Gewicht ca.: 24 g (0.05 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
continuously closed cup, flammability, flash point, ICS Number Code 75.080 (Petroleum products in general)
Significance and Use | ||||||||||||||||
5.1 The flash point temperature is one measure of the tendency of the test specimen to form a flammable mixture with air under controlled laboratory conditions. It is only one of a number of properties which must be considered in assessing the overall flammability hazard of a material. 5.2 Flash point is used in shipping and safety regulations to define flammable and combustible materials and for classification purposes. This definition may vary from regulation to regulation. Consult the particular regulation involved for precise definitions of these classifications. 5.3 This test method can be used to measure and describe the properties of materials in response to heat and an ignition source under controlled laboratory conditions and shall not be used to describe or appraise the fire hazard or fire risk of materials under actual fire conditions. However, results of this test method may be used as elements of a fire risk assessment, which takes into account all of the factors which are pertinent to an assessment of the fire hazard of a particular end use. 5.4 Flash point can also indicate the possible presence of highly volatile and flammable materials in a relatively nonvolatile or nonflammable material, such as the contamination of lubricating oils by small amounts of diesel fuel or gasoline. This test method was designed to be more sensitive to potential contamination than Test Method D6450. |
||||||||||||||||
1. Scope | ||||||||||||||||
1.1 This test method covers the determination of the flash point of fuels, lube oils, solvents and other liquids by a continuously closed cup tester utilizing a specimen size of 2 mL, cup size of 7 mL, with a heating rate of 2.5°C per minute. 1.1.1 Apparatus requiring a specimen size of 1 mL, cup size of 4 mL, and a heating rate of 5.5°C per minute must be run according to Test Method D6450. 1.2 This flash point test method is a dynamic method and depends on definite rates of temperature increase. It is one of the many flash point test methods available and every flash point test method, including this one, is an empirical method. 1.3 This test method utilizes a
closed but unsealed cup with air injected into the test
chamber.
1.4 This test method is suitable for testing samples with a flash point from 35 to 225°C. 1.5 If the user’s specification
requires a defined flash point method other than this method,
neither this method nor any other test method should be substituted
for the prescribed test method without obtaining comparative data
and an agreement from the specifier.
1.6 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6.1 Temperatures are in degrees Celsius, pressure in kilo-Pascals. 1.7 This standard does not
purport to address all of the safety concerns, if any, associated
with its use. It is the responsibility of the user of this standard
to establish appropriate safety and health practices and determine
the applicability of regulatory limitations prior to use.
Standard Test Methods for Flash Point by
Pensky-Martens Closed Cup Tester ISO Guide 35 Certification of Reference
MaterialsGeneral and Statistical Principles ISO Guide 34 Standard Practice for Sampling Industrial
Chemicals Standard Practice for Statistical
Assessment and Improvement of Expected Agreement Between Two Test
Methods that Purport to Measure the Same Property of a Material Standard Test Method for Flash Point by
Continuously Closed Cup (CCCFP) Tester (Includes all amendments and
changes 7/27/2021). Standard Practice for Automatic Sampling
of Petroleum and Petroleum Products (Includes all amendments and
changes 3/24/2023). Standard Practice for Manual Sampling of
Petroleum and Petroleum Products |
Historisch
1.6.2009
Historisch
15.6.2013
Historisch
1.10.2009
Historisch
1.6.2011
Historisch
1.6.2014
Historisch
1.5.2014
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-11-04 (Zahl der Positionen: 2 209 323)
© Copyright 2024 NORMSERVIS s.r.o.