Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Test Method for Cone/Plate Viscosity at a 500 s-1 Shear Rate
Automatische name übersetzung:
Standard Test Method for Kegel / Platte-Viskosität bei 500 s-1 Schergeschwindigkeit
NORM herausgegeben am 1.2.2012
Bezeichnung normen: ASTM D7395-07(2012)
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.2.2012
SKU: NS-38353
Zahl der Seiten: 3
Gewicht ca.: 9 g (0.02 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
No. 4 Ford cup-alternative to, rheology-paints/related coatings/materials, viscometer-cone/plate, viscosity-paints/related coatings/materials, Viscosity--paints/related coatings/materials, ICS Number Code 87.040 (Paints and varnishes)
Significance and Use | ||||
This test has been used to measure viscosities of automotive topcoats in place of No. 4 Ford cup measurements and has provided an equivalent ability to evaluate whether the paint meets specifications and is sprayable. The method could be considered as an alternative to No. 4 Ford cup and other efflux cup measurements for other products as well. The type of viscometer described in this method gives better temperature control than Ford and other efflux cups and is expected to give better precision. This test method is suitable for all paints and related materials whether they are Newtonian in behavior or not. |
||||
1. Scope | ||||
1.1 This test method covers the determination of the viscosity of paints and related products using a cone/plate viscometer at a shear rate of 500 s-1. 1.2 Viscosity values obtained by this method may be used as an alternative to results from No. 4 Ford cup measurements. The values from this method do not replicate Ford cup results, but can be used for quality control, producer-user specifications and viscosity reduction in the same manner that Ford cups are used. 1.3 If viscosity at a higher shear rate is needed, Test Method D4287, which describes viscosity measurement at 10 000 to 12 000 s-1 may be used. 1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||
2. Referenced Documents | ||||
|
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Vorschriften verwenden?
Wir bieten Ihnen Lösungen, damit Sie immer nur die gültigen (aktuellen) legislativen Vorschriften verwenden könnten.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-11-22 (Zahl der Positionen: 2 206 568)
© Copyright 2024 NORMSERVIS s.r.o.