Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Test Method for Determination of Fuel Filter Blocking Potential of Biodiesel (B100) Blend Stock by Cold Soak Filtration Test (CSFT) (Includes all amendments And changes 11/10/2017).
Automatische name übersetzung:
Standard Test Methode zur Bestimmung der Kraftstofffilter Sperrpotential von Biodiesel (B100) Mischkomponente von Cold Soak Filtrationstest (CSFT)
NORM herausgegeben am 1.11.2012
Bezeichnung normen: ASTM D7501-12a
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.11.2012
SKU: NS-38625
Zahl der Seiten: 6
Gewicht ca.: 18 g (0.04 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
biodiesel, biodiesel blend, diesel fuel, filter blocking potential, glass fiber filter, laboratory filtration, low temperature operability, middle distillate fuel, ICS Number Code 75.160.20 (Liquid fuels)
Significance and Use | ||||||||
5.1 Some substances that are soluble or appear to be soluble in biodiesel (B100) at room temperature will, upon cooling to temperatures above the cloud point or standing at room temperature for extended periods, come out of solution. This phenomenon has been observed in both B100 and BXX blends. These substances can cause filter plugging. This method provides an accelerated means of assessing the presence of these substances in B100 and their propensity to plug filters. 5.1.1 B100 biodiesel fuels that give short filtration times are expected to give satisfactory operation of BXX blends at least down to the cloud point of the biodiesel blends. 5.2 The test method can be used in specifications as a means of controlling levels of minor filter plugging components in biodiesel and biodiesel blends. |
||||||||
1. Scope | ||||||||
1.1 This test method covers the determination by filtration time after cold soak of the suitability for a biodiesel (B100) blend stock that meets all other requirements of Specification D6751 and has a cloud point below 20°C (68°F) to provide adequate low temperature operability performance to at least the cloud point of the finished blend. 1.2 The formal precision of this test method is included in 13.1 on Precision. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||
2. Referenced Documents | ||||||||
|
Historisch
1.5.2014
Historisch
1.11.2012
Historisch
15.2.2010
Historisch
1.5.2014
Historisch
1.11.2012
Historisch
1.5.2010
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Vorschriften verwenden?
Wir bieten Ihnen Lösungen, damit Sie immer nur die gültigen (aktuellen) legislativen Vorschriften verwenden könnten.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-11-22 (Zahl der Positionen: 2 206 568)
© Copyright 2024 NORMSERVIS s.r.o.