Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Test Method for Analysis of Ethyl tert-Butyl Ether (ETBE) by Gas Chromatography
Automatische name übersetzung:
Standard-Testverfahren zur Analyse von Ethyl-tert.-butylether (ETBE) durch Gaschromatographie
NORM herausgegeben am 15.5.2012
Bezeichnung normen: ASTM D7796-12
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 15.5.2012
SKU: NS-39126
Zahl der Seiten: 6
Gewicht ca.: 18 g (0.04 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
ETBE, ethyl tert-butyl ether, open tubular column gas chromatography, ICS Number Code 71.080.60 (Alcohols. Ethers), 75.160.20 (Liquid fuels)
Significance and Use | ||||||||||||||||
5.1 The presence of impurities in ETBE product can have a deleterious effect upon the value of ETBE as a fuel additive. Oxygenate and olefin contents are of primary concern. This test method provides a knowledge of the composition of ETBE product. This is useful in the evaluation of process operations control, in the valuation of the product, and for regulatory purposes. |
||||||||||||||||
1. Scope | ||||||||||||||||
1.1 This test method covers the determination of the purity of ethyl tert-butyl ether (ETBE) by gas chromatography. It also provides a procedure to measure impurities in ETBE such as C4 to C12 olefins, methyl, isopropyl and tert-butyl alcohols, methyl sec-butyl and methyl tert-amyl ethers, acetone, and methyl ethyl ketone. 1.2 This test method is not applicable to the determination of ETBE in gasoline. 1.3 Water cannot be determined by this test method and shall be measured by a procedure such as Test Method D6304 and the result used to normalize the chromatographic values. 1.4 Most of the impurities in ETBE are resolved by the test method, however, some co-elution is encountered. 1.5 This test method is inappropriate for impurities that boil at temperatures higher than 180°C or for impurities that cause poor or no response in a flame ionization detector, such as water. 1.6 The values stated in SI units of measurement are preferred and used throughout the standard. Alternate units, in common usage, are also provided to improve clarity and aid the user of this test methods. 1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||
2. Referenced Documents | ||||||||||||||||
|
Historisch
1.2.2011
Historisch
1.5.2013
Historisch
1.10.2013
Historisch
15.12.2012
Historisch
1.6.2010
Historisch
1.6.2010
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-11-04 (Zahl der Positionen: 2 209 323)
© Copyright 2024 NORMSERVIS s.r.o.