Standard Test Method for Oxidation Characteristics of Inhibited Mineral Oils
Name übersetzen
NORM herausgegeben am 1.6.2020
Bezeichnung normen: ASTM D943-20
Ausgabedatum normen: 1.6.2020
SKU: NS-1000026
Zahl der Seiten: 11
Gewicht ca.: 33 g (0.07 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
acid number, circulating oils, corrosion, hydraulic oils, inhibited steam-turbine oils, iron-coffer catalyst, metal catalyst, oxidation, oxidation lifetime, oxidation stability, test life, turbine oils,, ICS Number Code 75.100 (Lubricants, industrial oils and related products)
Significance and Use | ||||||||||||||||||||||||
5.1 This test method is widely used for specification purposes and is considered of value in estimating the oxidation stability of lubricants, especially those that are prone to water contamination. It should be recognized, however, that correlation between results of this method and the oxidation stability of a lubricant in field service may vary markedly with field service conditions and with various lubricants. The precision statement for this method was determined on steam turbine oils. Note 1: Furthermore, in the course of testing a lubricant by
this method, other signs of deterioration, such as sludge formation
or catalyst coil corrosion, may appear that are not reflected in
the calculated oxidation lifetime. The subcommittee responsible for
this method is investigating the application of alternative
criteria for evaluation of lubricants using this test apparatus.
Test Method D4310 is now
available for sludge measurement.
|
||||||||||||||||||||||||
1. Scope | ||||||||||||||||||||||||
1.1 This test method covers the evaluation of the oxidation stability of inhibited steam-turbine oils in the presence of oxygen, water, and copper and iron metals at an elevated temperature. This test method is limited to a maximum testing time of 10 000 h. This test method is also used for testing other oils, such as hydraulic oils and circulating oils having a specific gravity less than that of water and containing rust and oxidation inhibitors. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.2.1 Exception—The values in parentheses in the figures are provided for information for those using old equipment based on non-SI units. 1.3 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |
||||||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||||||
|
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-12-22 (Zahl der Positionen: 2 217 000)
© Copyright 2024 NORMSERVIS s.r.o.