Standard Specification for ASTM Liquid-in-Glass Thermometers
Automatische name übersetzung:
Standard-Spezifikation für ASTM & ensp; Flüssig-in-Glasthermometer
NORM herausgegeben am 1.5.2014
Bezeichnung normen: ASTM E1-14
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.5.2014
SKU: NS-40066
Zahl der Seiten: 51
Gewicht ca.: 153 g (0.34 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
bulb, liquid-in-glass thermometers, standard specification, stem, temperature, thermometer, ICS Number Code 17.200.20 (Temperature-measuring instruments)
1. Scope | ||||||||
1.1 This specification covers liquid-in-glass thermometers graduated in degrees Celsius or degrees Fahrenheit that are frequently identified and used in methods under the jurisdiction of the various technical committees within ASTM. The various thermometers specified are listed in Table 1. The inclusion of an IP number in Table 1 indicates, where appearing, that the thermometer specification has been jointly agreed upon by the British Institute of Petroleum (IP) and ASTM. 1.2 This specification also covers adjustable-range enclosed-scale thermometers, graduated in degrees Celsius, which are used in ASTM methods. 1.3 The enclosed-scale thermometers are commonly called Beckmann thermometers. They are suitable for measuring small temperature differences not exceeding 6 °C within a larger range of temperature. The thermometers are unsuitable for measuring Celsius- or kelvin-scale temperatures unless they have been compared with standard instruments immediately before use. 1.4 An alphabetic list of the ASTM Thermometers included in this standard is given in Table 2. 1.5 A list of ASTM Thermometers is given in Table 3 to facilitate selection according to temperature range, immersion, and scale-error requirements. Note 1: For a listing of thermometers recommended for general
laboratory use, the Scientific Apparatus Makers Association
Specifications for General Purpose Glass Laboratory Thermometers
may be consulted.Note 2: It has been found by experience that these ASTM
Thermometers, although developed in general for specific tests, may
also be found suitable for other applications, thus precluding the
need for new thermometer specifications differing in only minor
features. However, it is suggested that technical committees
contact Subcommittee E20.05 before choosing a currently specified
thermometer for a new method to be sure the thermometer will be
suitable for the intended application.
1.6 The thermometers found in Table 1 contain mercury, mercury thallium eutectic alloy, or toluene or other suitable liquid colored with a permanent red dye. For low-hazard precision non-mercury alternatives to E1 thermometers, see Specification E2251. 1.7 1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||
2. Referenced Documents | ||||||||
|
Historisch
1.11.2013
Historisch
1.5.2011
Historisch
1.5.2013
Historisch
1.5.2014
Historisch
1.5.2011
Historisch
1.5.2009
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-11-07 (Zahl der Positionen: 2 209 910)
© Copyright 2024 NORMSERVIS s.r.o.