Standard Practice for Electromagnetic (Eddy-Current) Examination of Type F-Continuously Welded (CW) Ferromagnetic Pipe and Tubing Above the Curie Temperature
Automatische name übersetzung:
Standard Praxis für Elektromagnetische ( Eddy - Current ) Untersuchung der Type F- gehend geschweißt (CW) ferromagnetische Rohre und Schläuche über die Curietemperatur
NORM herausgegeben am 10.12.1998
Bezeichnung normen: ASTM E1033-98
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 10.12.1998
SKU: NS-40202
Zahl der Seiten: 3
Gewicht ca.: 9 g (0.02 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
Austenitic steel-pipe, Austenitic steel-tube, Continuous welding, Curie temperature, Discontinuities, Electromagnetic (eddy current) testing, Ferromagnetic pipe/tube, Ferrous metals/alloys, Nonmagnetic metals, Piping systems, Steel pipe-austenitic alloy, Steel pipe-nondestructive testing, Steel tube-austenitic alloy, Steel tube-nondestructive testing, Welding/welds-nondestructive testing, pipe/tube-ferromagnetic (type F, continuously welded (CW)),
1. Scope | ||||||||||||
1.1 This practice covers a procedure for in-line, eddy-current examination of continuously welded (CW) ferromagnetic pipe and tubing at temperatures above the Curie temperature (approximately 1400°F (760°C), where the pipe is substantially nonmagnetic or austenitic. 1.2 This practice is intended for use on tubular products having nominal diameters of 1/2 in. (12.7 mm) to 4 in. (101.6 mm). These techniques may be used for larger- or smaller-diameter pipe and tubing as specified by the using parties. 1.3 This practice is specifically applicable to eddy-current examination using encircling coils, or probe coils. 1.4 This practice does not establish acceptance criteria. They must be established by the using parties. 1.5 The values stated in inch-pound units are to be regarded as standard. The SI units in parentheses may be approximate. 1.6 This standard does not purport to address the safety problems associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||
2. Referenced Documents | ||||||||||||
|
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-09-09 (Zahl der Positionen: 2 346 212)
© Copyright 2024 NORMSERVIS s.r.o.