Standard Guide for Evaluating Characteristics of Ultrasonic Search Units
Automatische name übersetzung:
Standard-Handbuch für die Bewertung von Eigenschaften von Ultraschall-Suche Units
NORM herausgegeben am 1.1.2014
Bezeichnung normen: ASTM E1065/E1065M-14
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.1.2014
SKU: NS-40317
Zahl der Seiten: 23
Gewicht ca.: 69 g (0.15 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
aperture, bandwidth, characterization, contact testing, depth of field, focal point, frequency response, immersion testing, peak frequency, search unit, sound beam profile, time response, ultrasound, ICS Number Code 17.140.01 (Acoustic measurements and noise abatement in general)
Significance and Use | ||||
5.1 This practice is intended to provide standardized procedures for evaluating ultrasonic search units. It is not intended to define performance and acceptance criteria, but rather to provide data from which such criteria may be established. 5.2 These procedures are intended to evaluate the characteristics of single-element piezoelectric search units. 5.3 Implementation may require more detailed procedural instructions in a format of the using facility. 5.4 The measurement data obtained may be employed by users of this practice to specify, describe, or provide a performance criteria for procurement and quality assurance, or service evaluation of the operating characteristics of ultrasonic search units. All or portions of the practice may be used as determined by the user. 5.5 The measurements are made primarily under pulse-echo conditions. To determine the relative performance of a search unit as either a transmitter or a receiver may require additional tests. 5.6 While these procedures relate to many of the significant parameters, others that may be important in specific applications may not be treated. These might include power handling capability, breakdown voltage, wear properties of contact units, radio-frequency interference, and the like. 5.7 Care must be taken to ensure that comparable measurements are made and that users of the practice follow similar procedures. The conditions specified or selected (if optional) may affect the test results and lead to apparent differences. 5.8 Interpretation of some test results, such as the shape of the frequency response curve, may be subjective. Small irregularities may be significant. Interpretation of the test results is beyond the scope of this practice. 5.9 Certain results obtained using the procedures outlined may differ from measurements made with ultrasonic test instruments. These differences may be attributed to differences in the nature of the experiment or the electrical characteristics of the instrumentation. 5.10 The pulse generator used to obtain the frequency response and time response of the search unit must have a rise time, duration, and spectral content sufficient to excite the search unit over its full bandwidth, otherwise time distortion and erroneous results may result. |
||||
1. Scope | ||||
1.1 This practice covers measurement procedures for evaluating certain characteristics of ultrasonic search units (also known as “probes”) that are used with ultrasonic testing instrumentation. This practice describes means for obtaining performance data that may be used to define the acoustic and electric responses of ultrasonic search units. 1.2 The procedures are designed to measure search units as individual components (separate from the ultrasonic test instrument) using commercial search unit characterization systems or using laboratory instruments such as signal generators, pulsers, amplifiers, oscilloscopes, and waveform analyzers. 1.3 The procedures are applicable to manufacturing acceptance and incoming inspection of new search units or to periodic performance evaluation of search units throughout their service life. 1.4 The procedures in Annex A1 – Annex A6 are generally applicable to ultrasonic search units operating within the 0.4 to 10 MHz range. 1.5 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||
2. Referenced Documents | ||||
|
Historisch
1.2.2013
Historisch
15.1.2008
Historisch
1.3.2014
Historisch
1.9.2010
Historisch
1.5.2010
Historisch
15.6.2012
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Vorschriften verwenden?
Wir bieten Ihnen Lösungen, damit Sie immer nur die gültigen (aktuellen) legislativen Vorschriften verwenden könnten.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-12-13 (Zahl der Positionen: 2 215 533)
© Copyright 2024 NORMSERVIS s.r.o.