Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Practice for Sampling Zooplankton with a Clarke-Bumpus Plankton Sampler
Automatische name übersetzung:
Standard Praxis für Sampling Zooplankton mit einem Clarke-Bumpus Plankton Sampler
NORM herausgegeben am 1.12.2012
Bezeichnung normen: ASTM E1199-87(2012)
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.12.2012
SKU: NS-40838
Zahl der Seiten: 2
Gewicht ca.: 6 g (0.01 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
ICS Number Code 13.060.30 (Sewage water)
Significance and Use | ||||
4.1 The advantages of the Clarke-Bumpus plankton sampler are as follows: 4.1.1 It will sample a discrete depth or multiple depths, depending upon the sampling design. 4.1.2 It is a slow to medium speed sampler requiring a towing speed of three to five knots. 4.1.3 The sample size can be easily controlled. 4.1.4 The sampler is lightweight and can be used without auxiliary equipment. 4.1.5 It has a relatively high filtration efficiency factor of 0.88. 4.1.6 It is a versatile sampler and can be used in all but the shallowest waters. 4.1.7 The flowmeter records the amount of water that passes into the net. 4.1.8 Overspill of water at the mouth of the net due to excess speed of towing is of minimal consequence. 4.2 The disadvantages of the Clarke-Bumpus plankton sampler are as follows: 4.2.1 The flowmeter requires frequent maintenance including calibration and lubrication. 4.2.2 It is not suitable for use in very small areas or shallow waters. 4.3 There are several special considerations that shall be observed when using a Clarke-Bumpus sampler. They are: 4.3.1 The flowmeter should be calibrated and serviced frequently to ensure efficient and accurate operation. 4.3.2 The sampler is relatively fragile, particularly the closing device and flowmeter. This necessitates careful deployment and recovery procedures. 4.3.3 Following each collection, the net must be thoroughly washed. 4.3.4 Special attention must be given to the strength of the cable and its attachment to avoid loss of the sampler. 4.3.5 The sampler should not be used in beds of macrophytes, in waters containing submerged objects, or close to the bottom. 4.3.6 The net should be inspected frequently for pin-size holes, tears, net deterioration, and other anomalies. 4.3.7 Following use, the wet net should be suspended full length in the air in subdued light and allowed to dry. |
||||
1. Scope | ||||
1.1 This practice covers the procedures for obtaining quantitative samples of a zooplankton community by use of a Clarke-Bumpus plankton sampler. 1.2 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||
2. Referenced Documents | ||||
|
Historisch
1.9.2012
Historisch
1.9.2011
Historisch
1.4.2013
Historisch
1.4.2013
Historisch
15.1.2008
Historisch
1.5.2008
Bereitstellung von aktuellen Informationen über legislative Vorschriften in der Sammlung der Gesetze bis zum Jahr 1945.
Aktualisierung 2x pro Monat!
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-11-22 (Zahl der Positionen: 2 206 568)
© Copyright 2024 NORMSERVIS s.r.o.