Standard Practice for Verification and Use of Control Charts in Spectrochemical Analysis (Withdrawn 2019)
Automatische name übersetzung:
Standard Praxis für Prüfung und Einsatz von Regelkarten in spektrochemische Analyse
NORM herausgegeben am 1.10.2010
Bezeichnung normen: ASTM E1329-10
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.10.2010
SKU: NS-41322
Zahl der Seiten: 12
Gewicht ca.: 36 g (0.08 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
confidence interval, control charts, normalization, standardization, verification, Calibration--spectrochemical analysis instrumentation, Confidence interval/limit/coefficient, Control charts, Data analysis--spectrochemical, Instrumental measurement--spectrochemical, Normalization, Quality control (QC), Radiation exposure, Spectral data--metals/alloys, Spectrochemical analysis, Spectrometry, Spectrophotometry, Spectroscopy, Statistical methods, Verification
Significance and Use | ||||||||||||
Consistency in analysis depends on being aware of a significant change in instrumental response, such as that caused by drift or changes in analytical precision, or both, and taking corrective action. The usual corrective action for drift is standardization. Standardization, however, when there is no real need, can only broaden the spread of subsequent analyses. One purpose of this practice is to set guidelines that will avoid “unnecessary standardization.” To control manufacturing processes, there must be confidence that a consistent material is being produced and that the analysis of the material is reliable. For assurance that the material meets specification, a purchaser may require the supporting record of control charts to assess that proper analytical control has been maintained. Ideally, variations in analytical results may be held to chance causes. The concept of a confidence interval or limits on a control chart is based on what can be expected when all normal precautions are exercised. When results appear to go out of control, the analyst should consider and correct what might be an assignable cause. As experience is accumulated, however, it may not seem unusual for readings to drift with time as optics degrade, detector response changes, or excitations conditions change, for example, when deposits build up on a counter electrode (a correctable assignable cause), or the longer range effects as an X-ray tube deteriorates. |
||||||||||||
1. Scope | ||||||||||||
1.1 This practice covers procedures for determining if a spectrochemical analysis is under statistical control. 1.2 Criteria are presented for determining when corrective action is required. 1.3 Control will be effected by using verifiers to test instrument response. It is recommended, although not required, that this be accompanied by the plotting of control charts. 1.4 The preparation of control charts is described. 1.5 Limitations—The procedures that are described do not apply to analyses that require a calibration each time a set of analyses is run. Reference is made specifically to atomic emission spectrometry, but the practice has a more general application. 1.6 This practice does not apply to validation procedures that monitor the correctness of calibration. |
||||||||||||
2. Referenced Documents | ||||||||||||
|
Historisch
1.12.2012
Historisch
1.9.2008
Historisch
1.2.2014
Historisch
1.9.2009
Historisch
1.3.2011
Historisch
1.7.2011
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-12-22 (Zahl der Positionen: 2 217 000)
© Copyright 2024 NORMSERVIS s.r.o.