Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Practice for Reducing the Effect of Variability of Color Measurement by Use of Multiple Measurements (Includes all amendments And changes 11/28/2014).
Automatische name übersetzung:
Standard Praxis zur Reduzierung der Wirkung der Variabilität der Farbmessung durch die Verwendung von Mehrfachmessungen
NORM herausgegeben am 1.6.2008
Bezeichnung normen: ASTM E1345-98(2008)e1
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.6.2008
SKU: NS-41375
Zahl der Seiten: 5
Gewicht ca.: 15 g (0.03 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
color, color difference, color measurement, color tolerances, Color--paints/related coatings/materials, Instrumental measurement--color/light, Statistical methods--paints/related coatings, Tolerances--paints/related coatings/materials, Variability, Visual examination--color, ICS Number Code 17.180.20 (Colours and measurement of light)
Significance and Use | ||||||||||||||||
This practice should be used whenever measured color-scale or color-difference-scale values are to be compared to an established tolerance. In this way it can be demonstrated quantitatively that the sampling and measurement procedures are adequate to allow an unambiguous decision as to whether or not the mean results are within tolerance. This practice is based on portions of SAE Practice J 1545, as it applies to painted or plastic automotive parts. It is generally applicable to object colors in various materials. Textured materials, such as textiles, may require special consideration (see SAE Practice J 1545 and STP 15D Manual on Presentation of Data and Control Chart Analysis ). While Practice E 178 deals with outliers, it does not include definitions relating to the box and whisker technique. The definition of an outlier is operational and a little vague because there is still considerable disagreement about what constitutes an outlier. In any normally distributed population, there will be members that range from minus to plus infinity. Theoretically, one should include any member of the population in any sample based on estimates of the population parameters. Practically, including a member that is found far from the mean within a small sample, most members of which are found near the mean, will introduce a systematic bias into the estimate of the population parameters (mean, standard deviation, standard error). Such a bias is in direct contrast with the goal of this practice, namely, to reduce the effects of variability of measurement. For the purposes of this practice, no distinction is made between errors of sampling and members of the tails of the distribution. Practice E 178 has several methods and significance tables to attempt to differentiate between these two types of extreme values. |
||||||||||||||||
1. Scope | ||||||||||||||||
1.1 Reduction of the variability associated with average color or color-difference measurements of object-color specimens is achieved by statistical analysis of the results of multiple measurements on a single specimen, or by measurement of multiple specimens, whichever is appropriate. 1.2 This practice provides a means for the determination of the number of measurements required to reduce the variability to a predetermined fraction of the relevant color or color-difference tolerances. 1.3 This practice is general in scope rather than specific as to instrument or material. |
||||||||||||||||
2. Referenced Documents | ||||||||||||||||
|
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Vorschriften verwenden?
Wir bieten Ihnen Lösungen, damit Sie immer nur die gültigen (aktuellen) legislativen Vorschriften verwenden könnten.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-11-22 (Zahl der Positionen: 2 206 568)
© Copyright 2024 NORMSERVIS s.r.o.