Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Guide for Conducting the Frog Embryo Teratogenesis Assay-Xenopus (FETAX)
Automatische name übersetzung:
Standard-Handbuch für die Durchführung der Frosch Embryo Teratogenese Assay-Xenopus (FETAX)
NORM herausgegeben am 1.12.2012
Bezeichnung normen: ASTM E1439-12
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.12.2012
SKU: NS-41755
Zahl der Seiten: 16
Gewicht ca.: 48 g (0.11 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
amphibia, developmental toxicity, FETAX, screening test, short-term chronic test, teratogenicity, Xenopus, ICS Number Code 07.080 (Biology. Botany. Zoology)
Significance and Use | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
5.1 FETAX is a rapid test for identifying potential developmental toxicity. Data may be extrapolated to other species including mammals. FETAX might be used to prioritize samples for further tests which use mammals. Validation studies using compounds with known mammalian or human developmental toxicity, or both, suggest that the predictive accuracy will exceed 85 % (2) . When evaluating a test material for mammalian developmental toxicity, FETAX must be used with and without a metabolic activation system (MAS). Use of this exogenous MAS should increase the predictive accuracy of the assay to approximately 95 %. The accuracy rate compares favorably with other currently available “ in vitro teratogenesis screening assays” (3). Any assay employing cells, parts of embryos, or whole embryos other than in vivo mammalian embryos is considered to be an in vitro assay. 5.2 It is important to measure developmental toxicity because embryo mortality, malformation, and growth inhibition can often occur at concentrations far less than those required to affect adult organisms. 5.3 Because of the sensitivity of embryonic and early life stages, FETAX provides information that might be useful in estimating the chronic toxicity of a test material to aquatic organisms. 5.4 Results from FETAX might be useful when deriving water quality criteria for aquatic organisms 5.5 FETAX results might be useful for studying structure-activity relationships between test materials and for studying bioavailability. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1. Scope | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1.1 This guide covers procedures for obtaining laboratory data concerning the developmental toxicity of a test material. The test utilizes embryos of the African clawed frog, 1.2 A renewal exposure regimen and the collection of the required mortality, malformation, and growth-inhibition data are described. Special needs or circumstances might require different types of exposure and data concerning other effects. Some of these modifications are listed in 1.3 These procedures are applicable to all chemicals either individually or in formulations, commercial products or mixtures that can be measured accurately at the necessary concentrations in water. With appropriate modification these procedures can be used to conduct tests on the effects of temperature, dissolved oxygen, pH, physical agents, and on materials such as aqueous effluents (see Guide E1192), surface and ground waters, leachates, aqueous and solid phase extracts, and solid phase samples, such as soils and sediments, particulate matter, sediment, and whole bulk soils and sediment. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. 1.5 This guide is arranged as follows:
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Historisch
1.10.2010
Historisch
1.10.2008
Historisch
1.1.2011
Historisch
1.10.2007
Historisch
1.3.2008
Historisch
1.10.2012
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-11-15 (Zahl der Positionen: 2 210 820)
© Copyright 2024 NORMSERVIS s.r.o.