Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Test Method for Water Penetration of Exterior Metal Roof Panel Systems by Uniform Static Air Pressure Difference
Automatische name übersetzung:
Standard Test Method for Water Eindringen von Außen Metall Dachplattensysteme von Uniform Statische Luftdruckdifferenz
NORM herausgegeben am 1.3.2011
Bezeichnung normen: ASTM E1646-95(2011)
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.3.2011
SKU: NS-42503
Zahl der Seiten: 6
Gewicht ca.: 18 g (0.04 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
air, air pressure, leakage, mastic, metal, panel, ponding, rain, roof, roof panel, pressure, side lap, side seam, static, structural, thermal expansion, water, water leakage, water penetration, water-spray, Air pressure testing--building constructions/materials, Exterior metal roof panel systems, Leak testing--building constructions/materials, Mastics, Panels, Ponding, Pressure testing--building constructions/materials, Rain, Roofing materials/applications, Roof panel systems, Side lap
Significance and Use | ||||||||||
This test method is a standard procedure for determining the resistance to water penetration under uniform positive static air pressure differences, and simulates wind driven rain imposed on sidelaps and rain that is free to drain while building a water head as it flows. The slope of the roof is significant. These factors shall be fully considered prior to specifying the test pressure difference. Note 1—In applying the results of tests by this method, note that the performance of a roof or its components, or both, may be a function of proper installation and adjustment. In service, the performance also depends on the rigidity of supporting construction, roof slope, and on the resistance of components to deterioration by various causes: corrosive atmosphere, aging, ice, vibration, thermal expansion and contraction, etc. It is difficult to simulate the identical complex wetting conditions that can be encountered in service, including large wind-blown water drops, increasing water drop impact pressures with increasing wind velocity, and lateral or upward moving air and water. Some designs are more sensitive than others to this upward moving water. Note 2—This is a test procedure. It is the responsibility of the specifying agency to determine the specimen construction, size, and test pressures after considering the method's guidelines. Practical considerations suggest that every combination of panel thickness, span, and design load need not be tested in order to substantiate product performance. Note 3—This test method shall not, by itself, be relied upon to form conclusions about overall water penetration through metal roofs. A roof contains many details. Although prescribed modifications are outside the scope of this test method, an experienced testing engineer is able to use the principles presented in this test method and generate significant data by isolating specific details and measuring leakage. |
||||||||||
1. Scope | ||||||||||
1.1 This test method covers the determination of the resistance of exterior metal roof panel systems to water penetration when water is applied to the outdoor face simultaneously with a static air pressure at the outdoor face higher than the pressure at the indoor face, that is, positive pressure. This test method is a specialized adaption of Test Method E331. 1.2 This test method is applicable to any roof area and is intended to measure only the water penetration associated with the field of roof including panel side laps and structural connections. It does not include leakage at openings or perimeter or any other details. 1.3 This test method is limited to specimens in which the side seams and attachments are clearly visible and in which the source of leakage is readily determined. Composite systems in which the source cannot be readily determined are outside the scope of this test method. 1.4 The proper use of this test method requires a knowledge of the principles of pressure and flow measurement. 1.5 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only and may be approximate. 1.6 The text of this test method references notes and footnotes excluding tables and figures, which provide explanatory material. These notes and footnotes shall not be considered as requirements of the test method. 1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see 7.1. |
||||||||||
2. Referenced Documents | ||||||||||
|
Historisch
1.5.2011
Historisch
1.1.2011
Historisch
15.10.2012
Historisch
1.1.2012
Historisch
15.1.2010
Historisch
1.10.2013
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-07-15 (Zahl der Positionen: 2 330 983)
© Copyright 2024 NORMSERVIS s.r.o.