Standard Practice for Testing Variable-Wavelength Photometric Detectors Used in Liquid Chromatography
Automatische name übersetzung:
Standard Praxis für Testing variabler Wellenlänge Photometrische Detektoren in der Flüssigkeitschromatographie
NORM herausgegeben am 1.3.2006
Bezeichnung normen: ASTM E1657-98(2006)
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.3.2006
SKU: NS-42540
Zahl der Seiten: 8
Gewicht ca.: 24 g (0.05 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
linearity, noise measurement, photometric detector, variable wavelength, wavelength accuracy, ICS Number Code 71.040.50 (Physicochemical methods of analysis)
Significance and Use | ||
Although it is possible to observe and measure each of the several characteristics of a detector under different and unique conditions, it is the intent of this practice that a complete set of detector specifications should be obtained under the same operating conditions. It should also be noted that to completely specify a detector’ capability, its performance should be measured at several sets of conditions within the useful range of the detector. The terms and tests described in this practice are sufficiently general that they may be used regardless of the ultimate operating parameters. Linearity and response time of the recorder or other readout device used should be such that they do not distort or otherwise interfere with the performance of the detector. This requires adjusting the gain, damping, and calibration in accordance with the manufacturer’directions. If additional electronic filters or amplifiers are used between the detector and the final readout device, their characteristics should also first be established. |
||
1. Scope | ||
1.1 This practice covers the testing of the performance of a variable-wavelength photometric detector (VWPD) used as the detection component of a liquid-chromatographic (LC) system operating at one or more wavelengths in the range 190 to 800 nm. Many of the measurements are made at 254 nm for consistency with Practice E 685. Measurements at other wavelengths are optional. 1.2 This practice is intended to describe the performance of the detector both independently of the chromatographic system (static conditions) and with flowing solvent (dynamic conditions). 1.3 For general liquid chromatographic procedures, consult Refs (1-9). 1.4 For general information concerning the principles, construction, operation, and evaluation of liquid-chromatography detectors, see Refs (10, 11)in addition to the sections devoted to detectors in Refs (1-7). 1.5 The values stated in SI units are to be regarded as standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||
2. Referenced Documents | ||
|
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-07-17 (Zahl der Positionen: 2 336 011)
© Copyright 2024 NORMSERVIS s.r.o.