Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Test Methods for Fire Tests of Fire-Resistive Barrier Systems for Electrical System Components
Automatische name übersetzung:
Standard-Prüfverfahren für Brandversuche von feuerbeständigen Schutzwandsysteme für elektrische Systemkomponenten
NORM herausgegeben am 1.7.2014
Bezeichnung normen: ASTM E1725-14
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.7.2014
SKU: NS-42786
Zahl der Seiten: 11
Gewicht ca.: 33 g (0.07 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Ignitability and burning behaviour of materials and productsElectrical engineering in general
Keywords:
air drop, cable tray, conduit, electrical system components, fire resistance rating, fire-resistive barrier systems, fire-test-response method, junction box, open run cables, pull box, raceway, thermal transmission, ICS Number Code 13.220.40 (Ignitability and burning behaviour of materials and products), 29.020 (Electrical engineering in general)
Significance and Use | ||||
4.1 These fire-test-response test methods evaluate, under the specified test conditions, the ability of a fire-resistive barrier system to inhibit thermal transmission to the electrical system component within. 4.2 In these procedures, the specimens are subjected to one or more specific sets of laboratory test conditions. If different test conditions are substituted or the end-use conditions are changed, it is not always possible by or from these test methods to predict changes in the fire test response characteristics measured. Therefore, the results are valid only for the fire test exposure conditions described in these procedures. 4.3 These test methods provide a measurement of the transmission of heat to the electrical system components within the barrier system. 4.4 These test methods provide qualification of a fireresistive barrier system as one element of an electrical system designed to maintain continuous operation of critical functions and processes for a specific fire resistance rating. 4.4.1 In addition to the temperature data provided by these test methods, numerous other factors, such as referenced in 1.4 shall be considered in specifying such a system. |
||||
1. Scope | ||||
1.1 These test methods cover fire-test-response. 1.2 These fire-test-response test methods provide information on the temperatures recorded on the electrical system component within a fire-resistive barrier system during the period of exposure. 1.3 This standard is used to measure and describe the response of materials, products, or assemblies to heat and flame under controlled conditions, but does not by itself incorporate all factors required for fire hazard or fire risk assessment of the materials, products, or assemblies under actual fire conditions. 1.4 Potentially important factors and fire characteristics not addressed by these test methods include, but are not limited to: 1.4.1 The performance of the fire-resistive barrier system constructed with components other than those tested. 1.4.2 An evaluation of the functionality of the electrical system within the fire-resistive barrier system. 1.4.3 An evaluation of the ampacity of the electrical system within the fire-resistive barrier system. 1.4.4 An evaluation of the smoke, toxic gases, corrosivity, or other products of heating. 1.4.5 A measurement of the flame spread characteristics over the surface of the fire-resistive barrier system. 1.4.6 An evaluation of through-penetration sealing methods. 1.4.7 Combustibility of materials in the fire-resistive barrier system or of the electrical system components. 1.4.8 The need for supports beyond those normally required. 1.4.9 Environmental conditions in the area of service. 1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. 1.7 Fire testing is inherently hazardous. Adequate safeguards for personnel and property shall be employed in conducting these tests. |
||||
2. Referenced Documents | ||||
|
Historisch
1.7.2010
Historisch
1.11.2013
Historisch
15.6.2010
Historisch
1.1.2013
Historisch
1.1.2007
Historisch
1.1.2010
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-11-01 (Zahl der Positionen: 2 208 817)
© Copyright 2024 NORMSERVIS s.r.o.