Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Test Method for Determining Tensile Breaking Strength of Glass Fiber Reinforcing Mesh for Use in Class PB Exterior Insulation and Finish Systems (EIFS), after Exposure to a Sodium Hydroxide Solution
Automatische name übersetzung:
Standard Test Methode zur Bestimmung der Zugbruchfestigkeit von Glasfaser-Verstärkungsgewebe für den Einsatz in Klasse PB Wärmedämmverbundsysteme ( WDVS ) , nachdem sie einer Natronlauge
NORM herausgegeben am 1.9.2006
Bezeichnung normen: ASTM E2098-00(2006)
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.9.2006
SKU: NS-44274
Zahl der Seiten: 3
Gewicht ca.: 9 g (0.02 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
alkali, breaking strength, exterior insulation and finish systems, glass fiber reinforcing mesh, tensile, ICS Number Code 59.100.10 (Textile glass materials)
Significance and Use | ||||||||
Glass fiber reinforcing meshes are used to strengthen EIFS. The reinforcing meshes are embedded into base coats that contain portland cement, which potentially exposes the glass fibers in the reinforcing meshes to weakening by the action of alkali. The breaking force following alkali exposure as determined by this method, is a factor used to comparatively evaluate the alkali resistance of EIFS glass fiber reinforcing meshes in the laboratory. This test method does not purport to simulate the conditions that may be encountered in service. The performance of an EIFS is a function of many factors, such as proper installation, rigidity of supporting construction and resistance of the EIFS to deterioration by other causes. |
||||||||
1. Scope | ||||||||
1.1 This test method covers procedures for determining the breaking force of glass fiber mesh following their conditioning in an alkali solution. The method is applicable to glass fiber mesh used in Class PB Exterior Insulation and Finish Systems (EIFS) with base coats that contain portland cement as an ingredient. 1.2 Breaking force is expressed both as force per unit width of mesh and as a percentage of the breaking force of the mesh that has not been exposed to alkali conditioning. 1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||
2. Referenced Documents | ||||||||
|
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-11-15 (Zahl der Positionen: 2 210 820)
© Copyright 2024 NORMSERVIS s.r.o.