Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Guide for Conducting Renewal Microplate-Based Life-Cycle Toxicity Tests with a Marine Meiobenthic Copepod (Withdrawn 2021)
Automatische name übersetzung:
Standard-Handbuch für die Durchführung Erneuerung Mikrotiterplatten-basierte Life-Cycle Toxizitätstests mit einem Marine-Meiobenthic Copepod
NORM herausgegeben am 1.12.2012
Bezeichnung normen: ASTM E2317-04(2012)
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.12.2012
SKU: NS-45021
Zahl der Seiten: 16
Gewicht ca.: 48 g (0.11 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
ICS Number Code 07.100.99 (Other standards related to microbiology)
Significance and Use | ||||||||||||||||
5.1 Protection of a species requires prevention of unacceptable effects on the number, health, and uses of individuals of that species. A life-cycle toxicity test is conducted to determine changes in the numbers of individuals and offspring of a test species resulting from effects of the test material on survival, growth, gender ratios, endocrine function, genetic expression, fertility and reproduction (1-3).3 Information might also be obtained on effects of the material on the health 5.2 Published information about the sensitivities of several meiobenthic copepods to several common metals and organic toxicants have been reviewed (5). For most compounds tested/published to date, 5.3 Results of life-cycle tests with 5.4 Results of life-cycle tests with 5.5 Results of life-cycle tests with 5.6 Results of a life-cycle test with 5.7 Results of life-cycle tests with 5.8 Results of life-cycle tests with 5.9 Life-cycle tests with 1.1 This guide describes procedures for obtaining laboratory data concerning the adverse effects of a test material added to seawater, but not to food, on the marine copepod Amphiascus tenuiremis , during continuous exposures of individuals, from immediately after birth, until after the beginning of reproduction using a 200 μL renewal microplate-culturing technique. The following data are checked and recorded during the test period: stage-specific survival, number of days it takes for development from a first stage nauplius to a reproductively mature copepod, gender ratios, number of days for a female to extrude first and subsequent broods, number of days between first (and subsequent) brood extrusion(s) and hatching of first-generation nauplii, number of hatched and surviving nauplii, number of unhatched or necrotic eggs and aborted unhatching eggsacs, and the total number of females able to produce viable offspring over the entire mating period. This microplate-based full life-cycle toxicity test has a duration of approximately 17 days for toxicants that do not delay development. These procedures probably will be useful for conducting life-cycle toxicity tests with other species of copepods, although modifications might be necessary. 1.2 These procedures are applicable to most chemicals, either individually, or in formulations, commercial products, or known mixtures, that can be measured accurately at the necessary concentration in water. With appropriate modifications these procedures can be used to conduct tests on temperature, dissolved oxygen, and pH and on such materials as aqueous effluents (see also Guide E1192), sediment pore waters, and surface waters. Renewal microplate tests might not be applicable to materials that have a high oxygen demand, are highly volatile, are rapidly transformed (biologically or chemically) in aqueous solutions, or are removed from test solutions in substantial quantities by the test chambers or organisms during the test. If the concentration of dissolved oxygen falls below 50 % of saturation, or the concentration of test material in the test solution decreases by more than 20 % between renewals, it might be desirable to renew the solutions more often. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory requirements prior to use. |
||||||||||||||||
2. Referenced Documents | ||||||||||||||||
|
Historisch
1.9.2012
Historisch
1.6.2014
Historisch
1.10.2009
Historisch
1.3.2009
Historisch
1.4.2008
Historisch
1.7.2013
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-11-22 (Zahl der Positionen: 2 206 568)
© Copyright 2024 NORMSERVIS s.r.o.