Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Test Method for Exposure of Firestop Materials to Severe Environmental Conditions
Automatische name übersetzung:
Standard Test Method for Exposition von Brandschutzmaterialien, um rauen Umgebungsbedingungen
NORM herausgegeben am 1.5.2014
Bezeichnung normen: ASTM E2785-14
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.5.2014
SKU: NS-46034
Zahl der Seiten: 8
Gewicht ca.: 24 g (0.05 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Fire-fightingIgnitability and burning behaviour of materials and products
Keywords:
accelerated, artificial, cold, environmental exposure, firestop, heat, humid, penetration, wet, ICS Number Code 13.220.10 (Fire-fighting),13.220.40 (Ignitability and burning behaviour of materials and products)
Significance and Use | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
5.1 This test method is intended to evaluate the material performance after exposure to a standardized set of severe environmental conditions. It is understood that these performance values are dependent upon these standardized exposure periods and environmental concentrations. Other values are possible if the exposure period or severe environmental concentration, or both, is changed. 5.2 This test method is intended to be used where the material is exposed to the specific extreme environmental condition in its intended field of application. 5.3 The user shall establish which properties are relevant to the application at hand, in order to determine the properties to be tested. 5.4 This test method is intended to
evaluate only the following types of materials, as defined by their
physical properties or chemical properties, or both, and used in
penetration firestops:
5.4.1 Endothermic, 5.4.2 Intumescent, 5.4.3 Insulative, 5.4.4 Ablative, and 5.4.5 Subliming. 5.5 This test method determines initial physical properties, chemical properties, or both, to allow comparison with physical properties, chemical properties, or both after exposure. The following properties are to be considered, as applicable: 5.5.1 Weight loss or gain, 5.5.2 Volume expansion, 5.5.3 Thermal conductivity, 5.5.4 Thermogravimetric analysis (TGA), 5.5.5 Differential scanning calorimetry (DSC), 5.5.6 Tensile strength and elongation, 5.5.7 Visual observations, and 5.5.8 Loss on ignition. 5.6 This test method uses the following exposures: 5.6.1 Elevated temperature, 5.6.2 High humidity, 5.6.3 Carbon dioxide and sulfur dioxide with moisture present, 5.6.4 Water immersion, 5.6.5 Temperature cycling, 5.6.6 Wet-freeze-dry cycling, and 5.6.7 Weathering. 5.7 This test method does not provide any information regarding the actual fire performance of the firestop before or after the exposure tests. 5.8 This test method will provide a comparison between formula and processing changes in materials. 5.9 This test method only provides for a comparison of the tested material before and after a standardized exposure process. 5.10 This test method shall be used as one element in evaluating materials or selecting firestop material(s) for a specific application. Other factors shall be considered, such as its fire performance as tested in accordance with Test Methods E814 or E119, flame spread as tested in accordance with Test Method E84, durability, and its compatibility with its adjacent materials. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||
1. Scope | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
1.1 This test method evaluates a change in physical properties, chemical properties, or both, of firestop materials after a standardized environmental exposure. This test method does not evaluate the fire performance of the firestop materials. 1.2 This test method establishes indicators that will aid in determining the use of the tested material in buildings. 1.3 This test method evaluates the properties of component products used within a firestop system, and does not evaluate the properties of assembled firestop systems. 1.4 This test method is intended to
be a screening method in the evaluation of the relative behavior of
a specific material before and after a standardized set of severe
exposure criteria. Individual tests are not intended to be the only
determining factor in evaluating or selecting a firestop material
because each test has limitations.
1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Historisch
1.8.2011
Historisch
1.8.2011
Historisch
1.1.2011
Historisch
1.8.2011
Historisch
1.1.2011
Historisch
1.6.2010
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-11-01 (Zahl der Positionen: 2 208 817)
© Copyright 2024 NORMSERVIS s.r.o.