Standard Test Method for Evaluating Thermal EMF Properties of Base-Metal Thermocouple Connectors
Automatische name übersetzung:
Standard Test Methode zur Bestimmung Thermal EMF Eigenschaften von Nichtedelmetall-Thermoelemente Stecker
NORM herausgegeben am 1.5.2013
Bezeichnung normen: ASTM E2820-13
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.5.2013
SKU: NS-46091
Zahl der Seiten: 6
Gewicht ca.: 18 g (0.04 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
connector emf, thermocouple connector, thermocouple contact, thermocouple pin, thermocouple socket, thermocouple terminal, ICS Number Code 17.200.20 (Temperature-measuring instruments)
Significance and Use | ||||||||||||||
5.1 A thermocouple connector, exposed to a temperature difference, contributes to the output of a thermocouple circuit. The output uncertainty allocated to the connector depends on the connector design and temperature gradient. 5.2 Connector performance can be classified based on the results of this method and used as part of a component specification. 5.3 The method can be used as an engineering tool for evaluating different connector designs tested under similar thermal conditions. |
||||||||||||||
1. Scope | ||||||||||||||
1.1 This standard describes a thermal emf test method for base-metal thermocouple connectors including Types E, J, K, N and T. Standard connectors such as found in Specifications E1129/E1129M and E1684 as well as non-standard connector configurations and connector components can be evaluated using this method. 1.2 The measured emf is reported as an equivalent temperature deviation or error relative to a reference thermocouple of the same type. This method can be used to verify deviations introduced by the connector greater than or equal to 1°C. 1.3 The connector is tested with thermocouple contacts axially aligned with a temperature gradient using a specified thermal boundary condition. The actual temperature difference developed across the connector and corresponding error will depend on the connector design. 1.4 Connector contacts are often fabricated from raw materials having temperature-emf relationships in accordance with Specification E230. However, verifying Specification E230 tolerances is not within the scope of this method. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||
2. Referenced Documents | ||||||||||||||
|
Historisch
1.11.2011
Historisch
1.5.2014
Historisch
1.11.2012
Historisch
1.4.2013
Historisch
1.5.2013
Historisch
1.5.2013
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-11-22 (Zahl der Positionen: 2 206 568)
© Copyright 2024 NORMSERVIS s.r.o.