Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen
Automatische name übersetzung:
Standard Test Methode zur Bestimmung der Geschwindigkeit der Luftaustritt durch Exterior Fenster, Fassaden und Türen unter bestimmten Druckdifferenzen über die Specimen
NORM herausgegeben am 1.3.2004
Bezeichnung normen: ASTM E283-04
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.3.2004
SKU: NS-46101
Zahl der Seiten: 5
Gewicht ca.: 15 g (0.03 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
air leakage, curtain walls, doors, fenestration, laboratory method, static pressure chamber, windows, ICS Number Code 91.120.10 (Thermal insulation of buildings)
Significance and Use | ||||
This test method is a standard procedure for determining the air leakage characteristics under specified air pressure differences at ambient conditions. Note 2—The air pressure differences acting across a building envelope vary greatly. The factors affecting air pressure differences and the implications or the resulting air leakage relative to the environment within buildings are discussed in the literature.3 ,4 ,5 These factors should be fully considered in specifying the test pressure differences to be used. Rates of air leakage are sometimes used for comparison purposes. Such comparisons may not be valid unless the components being tested and compared are of essentially the same size, configuration, and design. |
||||
1. Scope | ||||
1.1 This test method covers a standard laboratory procedure for determining the air leakage rates of exterior windows, curtain walls, and doors under specified differential pressure conditions across the specimen. The test method described is for tests with constant temperature and humidity across the specimen. 1.2 This laboratory procedure is applicable to exterior windows, curtain walls, and doors and is intended to measure only such leakage associated with the assembly and not the installation. The test method can be adapted for the latter purpose. Note 1—Performing tests at non-ambient conditions or with a temperature differential across the specimen may affect the air leakage rate. This is not addressed by this test method. 1.3 This test method is intended for laboratory use. Persons interested in performing field air leakage tests on installed units should reference Test Method E 783. 1.4 Persons using this procedure should be knowledgeable in the areas of fluid mechanics, instrumentation practices, and shall have a general understanding of fenestration products and components. 1.5 Throughout this test method, SI units are listed first in accordance with E06 metric policy, and shall be considered the primary units. Non-SI units are provided in parenthesis for reference purposes. 1.6 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statement see Section . |
||||