Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Practice for Measuring Coating Thickness by Magnetic-Field or Eddy-Current (Electromagnetic) Testing Methods
Automatische name übersetzung:
Standard Praxis für Schichtdickenmessung von Magnetfeld-oder Wirbelstrom (Elektromagnetische) Prüfverfahren
NORM herausgegeben am 1.7.2011
Bezeichnung normen: ASTM E376-11
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.7.2011
SKU: NS-46573
Zahl der Seiten: 5
Gewicht ca.: 15 g (0.03 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
coating thickness, eddy current probes, magnetic field, nondestructive testing, Coating thickness, Eddy current examination, Electrodeposited coatings, Electromagnetic (eddy current) testing, Magnetic testing--coating thickness, Mechanically deposited coatings, Steel--mechanically deposited coatings, Tin mill products (coating thickness), Zinc-coated steel sheet--specifications, Zinc-coated steel wire, Zinc coatings, ICS Number Code 17.040.20 (Properties of surfaces)
Significance and Use | ||||||||||||||||||||
General—No presently available thickness gauge is applicable to all combinations of coating-substrate thicknesses and materials. The limitations of a particular instrument are generally delineated by its manufacturer. Magnetic—Magnetic-type gauges measure either magnetic attraction between a magnet and a coating or its substrate, or reluctance of a magnetic flux path passing through the coating and substrate. These gauges are designed to measure thickness of a nonmagnetic coating on a magnetic substrate. Some of them will also measure thickness of nickel coatings on a magnetic or nonmagnetic substrate. Eddy Current—Eddy-current-type thickness gauges are electronic instruments that measure variations in impedance of an eddy-current inducing coil caused by coating thickness variations. They can only be used if the electrical conductivity of the coating differs significantly from that of the substrate. Accuracy—The accuracy of a measurement depends on the instrument, its calibration and standardization, and its operating conditions. The accuracy is also affected by the interferences listed in Section 5, such as part geometry (curvature), magnetic permeability, and surface roughness. Note 2—This practice allows the coating thickness to be determined within ±10 % of its true thickness or to within ±2.5 μm (or ±0.0001-in.), whichever is the greater. (See exceptions in Appendix X2.) |
||||||||||||||||||||
1. Scope | ||||||||||||||||||||
1.1 This practice covers the use of magnetic- and eddy-current-type thickness instruments (gauges) for nondestructive thickness measurement of a coating on a metal substrate. 1.2 More specific uses of these instruments are covered by Practice D7091 and the following test methods issued by ASTM: Test Methods B244, B499, B530, and G12. 1.3 Units—The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard. 1.4 Measurements made in accordance with this practice will be in compliance with the requirements of ISO 2178 as printed in 1982. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||
|
Historisch
1.11.2012
Historisch
1.10.2011
Historisch
1.10.2013
Historisch
1.8.2009
Historisch
1.6.2011
Historisch
1.11.2013
Letzte Aktualisierung: 2024-12-22 (Zahl der Positionen: 2 217 000)
© Copyright 2024 NORMSERVIS s.r.o.