Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Test Method for Water Penetration and Leakage Through Masonry
Automatische name übersetzung:
Standard Test Method for Eindringen von Wasser und Leckage durch Mauerwerk
NORM herausgegeben am 1.6.2008
Bezeichnung normen: ASTM E514-08
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.6.2008
SKU: NS-47050
Zahl der Seiten: 4
Gewicht ca.: 12 g (0.03 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
air-pressure, laboratory test, manometer, masonry, simulated wind driven rain, test chamber, water penetration, water spray pipe, Leak testing--building constructions/materials, Masonry assemblages, Water penetration--masonry materials/applications, ICS Number Code 91.080.30 (Masonry)
Significance and Use | ||||||
This test method provides information that aids in evaluating the effect of four principal variables: materials, coatings, wall design, and workmanship. Water penetration and leakage through masonry is significantly affected by air pressure in the test chamber. Data from tests made at different pressures are not comparable. The performance of a masonry wall is a function of materials, construction, wall design, and maintenance. In service the performance will also depend on the rigidity of supporting structure and on the resistance of components to deterioration by various causes, such as corrosion, vibration, thermal expansion and contraction, curing, and others. It is impossible to simulate the complex conditions encountered in service, such as variations in wind velocity, negative pressure, and lateral or upward moving air and water. Factors such as location, exposure, and wall openings should be considered. Given the complexity of variables noted above, this test method establishes comparative behavior between various masonry wall constructions in a given laboratory. Even when a single laboratory tests the same wall design utilizing the same wall materials and the same construction practices, variables such as the level of skill of the mason building the specimen, the temperature and humidity in the laboratory at the time of construction, curing of the specimen, the moisture contents of the materials used to build the specimen, and even the use or lack of use of a lime and water wash on the back of the specimen can affect the results of the test making reliable comparisons dubious. For these reasons and the multi-variables listed in 4.1, 4.2, and 4.3, a meaningful, useful, absolute wall leakage rating standard is impractical and discouraged. |
||||||
1. Scope | ||||||
1.1 This laboratory test method provides a procedure for determining the resistance to water penetration and leakage through unit masonry subjected to wind-driven rain. 1.2 The values stated in SI units are to be regarded as standard. The values in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For a specific hazard statement, see Section 6. |
||||||
2. Referenced Documents | ||||||
|
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-12-22 (Zahl der Positionen: 2 217 000)
© Copyright 2024 NORMSERVIS s.r.o.