Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Test Method for Measuring Fast-Neutron Reaction Rates by Radioactivation of Titanium
Automatische name übersetzung:
Standard Test Methode zur Messung Schnellneutronenreaktionsgeschwindigkeiten von Radioaktivierungs von Titan
NORM herausgegeben am 1.1.2013
Bezeichnung normen: ASTM E526-08(2013)
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.1.2013
SKU: NS-47095
Zahl der Seiten: 4
Gewicht ca.: 12 g (0.03 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
activation reaction, cross section, dosimetry, nuclear metrology, pressure vessel surveillance, reaction rate, titanium, ICS Number Code 17.240 (Radiation measurements), 27.120.30 (Fissile materials and nuclear fuel technology)
Significance and Use | ||||||||||||||||
5.1 Refer to Guide E844 for the selection, irradiation, and quality control of neutron dosimeters. 5.2 Refer to Test Method E261 for a general discussion of the determination of fast-neutron fluence rate with threshold detectors. 5.3 Titanium has good physical strength, is easily fabricated, has excellent corrosion resistance, has a melting temperature of 1675°C, and can be obtained with satisfactory purity. 5.4 46Sc has a half-life of 83.79 days.5.5 The isotopic content of natural titanium recommended for 46Ti is 8.25 %.3 5.6 The radioactive products of the neutron reactions 47Ti(n,p)47Sc (τ5.7 Contaminant activities (for example, 65Zn and 182Ta) might interfere with the analysis of 46Sc. See Sections 7.1.2 and 7.1.3 for more details on the 182Ta and 65Zn interference. 5.8 46Ti and 46Sc have cross sections for thermal neutrons of 0.59 and 8 barns, respectively5; therefore, when an irradiation exceeds a thermal-neutron fluence greater than about 2 × 1021 cm–2, provisions should be made to either use a thermal-neutron shield to prevent burn-up of 46Sc or measure the thermal-neutron fluence rate and calculate the burn-up. 5.9 Fig. 1 shows a plot of cross section versus neutron energy for the fast-neutron reactions of titanium which produce 46Sc [that is, NatTi(n,X)46Sc]. Included in the plot is the 46Ti(n,p) reaction6 and the 47Ti(n,np) contribution to the 46Sc production,1.1 This test method covers procedures for measuring reaction rates by the activation reactions 46Ti(n,p) 46Sc + 47Ti(n, np)46Sc. 1.2 The reaction is useful for
measuring neutrons with energies above approximately 4.4 MeV and
for irradiation times up to about 250 days (for longer
irradiations, see Practice E261).
1.3 With suitable techniques, fission-neutron fluence rates above 109 cm–2·s–1 can be determined. However, in the presence of a high thermal-neutron fluence rate, 46Sc depletion should be investigated. 1.4 Detailed procedures for other fast-neutron detectors are referenced in Practice E261. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||
2. Referenced Documents | ||||||||||||||||
|
Historisch
1.6.2010
Historisch
15.5.2011
Historisch
1.6.2011
Historisch
1.1.2012
Historisch
1.12.2008
Historisch
1.6.2011
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-12-22 (Zahl der Positionen: 2 217 000)
© Copyright 2024 NORMSERVIS s.r.o.