Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Test Methods for Destructive Shear Testing of Ball Bonds
Automatische name übersetzung:
Standard-Prüfverfahren für Zerstörungsfreie Prüfung von Schubkugel Bonds
NORM herausgegeben am 1.1.2013
Bezeichnung normen: ASTM F1269-13
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.1.2013
SKU: NS-49701
Zahl der Seiten: 9
Gewicht ca.: 27 g (0.06 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
ball bonds, shear testing, wire bonding, ICS Number Code 25.160.40 (Welding joints and welds)
Significance and Use | ||||||||||
5.1 Failure of microelectronic devices is often due to the failure of an interconnection bond. The most common type of interconnection bond is the thermosonic gold or copper wire bond. A very important element of this interconnection is the first bond or ball bond. These test methods can assist in maintaining control of the process for making ball bonds. They can be used to distinguish between weak and nonadherent ball bonds, of both, and bonds that are acceptably strong. 5.2 These test methods are appropriate for on-line use in process control, for process development, for purchase specifications, and for research in support of improved yield and reliability. Since the ball shearing method tests only the first bond in a microelectronic wire bond interconnection system, it must be used in a complementary fashion1.1 These test methods cover tests to determine the shear strength of a series of ball bonds made by either thermosonic or thermal compression techniques using either gold or copper wires. 1.2 These test methods cover ball
bonds made with small diameter (from 18 to 76-μm (0.0007 to
0.003-in.)) gold or copper wire of the type used in integrated
circuits and hybrid microelectronic assemblies, system on a chip,
and so forth.
1.3 These test methods can be used only when the ball height and diameter are large enough and adjacent interfering structures are far enough away to allow suitable placement and clearance (above the bonding pad and between adjacent bonds) of the shear test ram. 1.4 These test methods are destructive. They are appropriate for use in process development or, with a proper sampling plan, for process control or quality assurance. 1.5 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||