Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Test Method for Qualitative Analysis of Volatile Extractables in Microwave Susceptors Used to Heat Food Products (Withdrawn 2024)
Name übersetzen
NORM herausgegeben am 1.3.2019
Bezeichnung normen: ASTM F1519-98(2019)
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.3.2019
SKU: NS-951577
Zahl der Seiten: 5
Gewicht ca.: 15 g (0.03 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Cooking ranges, working tables, ovens and similar appliances
Keywords:
characteristic mass, diffusion trapping, extractables, volatile, gas chromatography/mass spectrometry, mass spectrometry, microwave, microwave heating, microwave oven, microwave susceptors, qualitative analysis, susceptor , susceptors, microwave,, ICS Number Code 97.040.20 (Cooking ranges, working tables, ovens and similar appliances)
Significance and Use | ||||||||
5.1 This test method is intended to identify volatile extractables that may be emitted from microwave susceptor material during use. It may be a useful procedure to assist in minimizing the amount and type of volatile extractables produced. The susceptor design, materials used or manufacturing processes involved can be evaluated. |
||||||||
1. Scope | ||||||||
1.1 This test method is applicable to complete microwave susceptors. 1.2 This test method covers a procedure for identifying volatile extractables which are released when a microwave susceptor sample is tested under simulated end use conditions. The extractables are identified using gas chromatography/mass spectrometry (GC/MS). 1.3 This test method was evaluated for the identification of a variety of volatile extractables at a level of 0.010 μg/in.2 of susceptor surface. For extractables not evaluated, the analyst should perform studies to determine the level of extractable at which identification is achievable. 1.4 The analyst is encouraged to run known volatile extractables and/or incorporate techniques such as gas chromatography/high resolution mass spectrometry (GC/HRMS), gas chromatography/infrared spectroscopy (GC/IR) or other techniques to aid in verifying the identity of or identifying unknown volatile extractables. The analyst is referred to Practice E260 for additional guidance. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |
||||||||
2. Referenced Documents | ||||||||
|
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-12-23 (Zahl der Positionen: 2 217 157)
© Copyright 2024 NORMSERVIS s.r.o.