Standard Specification for Indicators, Sight, Liquid Level, Direct and Indirect Reading, Tubular Glass/Plastic (Includes all amendments and changes 2/1/2018).
Name übersetzen
NORM herausgegeben am 1.1.2018
Bezeichnung normen: ASTM F2045-00(2018)e1
Ausgabedatum normen: 1.1.2018
SKU: NS-805953
Zahl der Seiten: 8
Gewicht ca.: 24 g (0.05 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Other standards related to shipbuilding and marine structures
This specification covers the requirements for direct and indirect reading sight liquid level indicators for general applications. General applications for indirect reading sight glasses are water and fuel service at working pressures 2.07 MPa (300 lb/in.2) and below, temperatures of 149°C (300°F) and below. Direct reading sight glass indicators may consist of glass or plastic tubes with fittings including shutoff valves. Glass tubes may be used for low shock direct reading sight glass indicators in which the fluid is not compatible with plastic. Indirect reading indicators may consist of a sealed chamber with a magnetic float or flag indicator. Indicator designs are classified as either direct reading or indirect reading. Qualification testing and quality conformance testing shall be performed to meet the requirements prescribed.
Keywords:
direct level indicator, indirect level indicator, liquid level indicator, sight glass,, ICS Number Code 47.020.99 (Other standards related to shipbuilding and marine structures)
1. Scope | ||||
1.1 This specification covers the requirements for direct and indirect reading sight liquid level indicators for general applications. General applications for indirect reading sight glasses are water and fuel service at working pressures 2.07 MPa (300 lb/in.2) and below, temperatures of 149°C (300°F) and below. General applications for direct reading sight glasses are applications in which the temperature does not exceed 66°C (150°F). 1.2 Direct reading sight glass indicators may consist of glass or plastic tubes with fittings including shutoff valves. Glass tubes may be used for low shock direct reading sight glass indicators in which the fluid is not compatible with plastic. 1.3 Indirect reading indicators may consist of a sealed chamber with a magnetic float or flag indicator. 1.4 Special requirements for naval shipboard applications are included in the supplement to this standard. 1.5 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard. 1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |
||||
2. Referenced Documents | ||||
|
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-09-18 (Zahl der Positionen: 2 350 413)
© Copyright 2024 NORMSERVIS s.r.o.