Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.
Standard Guide for Evaluating the Extent of Oxidation in Polyethylene Fabricated Forms Intended for Surgical Implants
Automatische name übersetzung:
Standard-Leitfaden zur Bewertung das Ausmaß der Oxidation in Polyethylen Zeugformen Bestimmt für chirurgische Implantate
NORM herausgegeben am 1.11.2013
Bezeichnung normen: ASTM F2102-13
Anmerkung: UNGÜLTIG
Ausgabedatum normen: 1.11.2013
SKU: NS-52838
Zahl der Seiten: 5
Gewicht ca.: 15 g (0.03 Pfund)
Land: Amerikanische technische Norm
Kategorie: Technische Normen ASTM
Keywords:
FTIR, implant, oxidation, oxidation index, UHMWPE, ICS Number Code 11.040.40 (Implants for surgery, prothetics and orthotics)
1. Scope | ||
1.1 This guide covers a method for the measurement of the relative extent of oxidation present in HDPE homopolymers and ultra-high-molecular-weight polyethylene (UHMWPE) intended for use in medical implants. The material is analyzed by infrared spectroscopy. The intensity (area) of the carbonyl absorptions (>C=O) centered near 1720 cm-1 is related to the amount of chemically bound oxygen present in the material. Other forms of chemically bound oxygen (C-O-C, C-O-O-C, C-O-H, and so forth) are not captured by this guide. 1.2 Although this guide may give the investigator a means to compare the relative extent of carbonyl oxidation present in various UHMWPE samples, it is recognized that other forms of chemically bound oxygen may be important contributors to these materials' characteristics. 1.3 FIG. 1 Typical FTIR Spectra of
Oxidized UHMWPE, Showing the Definition of an Area-Based Oxidation
Index Based on Normalization Using the 1370-cm -1
Peak
FIG. 2 FTIR Spectra Showing the
Carbonyl Absorption Bands
1.4 The following
precautionary caveat pertains only to the test method portion,
Section 5, of this specification: This standard may involve
hazardous materials, operations, and equipment. This standard does
not purport to address all of the safety concerns, if any,
associated with its use. It is the responsibility of the user of
this standard to establish appropriate safety and health practices
and determine the applicability of regulatory requirements prior to
use.
|
||
2. Referenced Documents | ||
|
Historisch
1.7.2011
Historisch
1.7.2011
Historisch
1.9.2010
Historisch
1.6.2011
Historisch
1.3.2014
Historisch
1.12.2010
Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.
Letzte Aktualisierung: 2024-12-22 (Zahl der Positionen: 2 217 000)
© Copyright 2024 NORMSERVIS s.r.o.